Help w/Adjusting SDR Max Fan Speeds for P4000 S1200RPL V3

$
0
0

Hello All,

I just put together a new server from an Intel P4000RP barebones chassis which comes with the S1200RPL board. On first power up it sounded like a jet engine and remained like that until I updated the bios, redetected the chassis, and did all the usual steps recommended. Now the fan speeds are totally fine when idle or under light load, but they increase to an irritatingly loud volume when running at high load.

 

Acoustic mode is already turned on in the BIOS, but I would like to go further as I am pretty confident I could half the max fan speed values and still be no where near overheating. The server has no hard drives, just SSDs, so there isn't much to keep cool in there other than the CPU. Unfortunately it will live in a room with 4 working people, so keeping the sound to a reasonable level is a priority even under max load. Obviously I will do some tests to make sure there is no danger of overheating.

 

Anyway, the issue is that I'm not sure which entry to modify. Unfortunately this being a newer board, the entries don't correspond to some of the past forum posts / tutorials I've read online. An example section from my S1200RP.sdr follows below. I'd ultimately like to adjust sys fan 1 and sys fan 4 while leaving the CPU fan settings alone. I see that "Temperature Threshold Boost Value" and "Ramp Step" are both 64, hexadecimal for 100. Is one or both of those what I need to decrease, or am I in the wrong place?

 

Really appreciate anyone's time and effort on this. Thanks!

 

_SDR_TYPE   C0

_SDR_TAG    'UPS_8X35NOSAS'

_REC_LEN    001C

 

   // Sensor Record Header

   0F0C           // Record ID

   51             // SDR Version

   C0             // Record Type

   17             // Record Length

 

   // Record Body Bytes

   570100         // Manufacturer ID

   0C             // Record Subtype Value (Fan Speed Control SDR Record, rev 2)

   02             // Record Version

   08             // FSC Record Type (08h = Main Domain)

   01             // Domain Mask

   F0             // Fan Profile Support

 

   // Domain Configuration

   01             // FSC Sub-Record Type (01h = Domain Configuration)

   14             // Normal Control Value

   64             // Ramp Step

   01             // Scan Rate

   64             // Fan Fault Boost Value

   64             // Temperature Threshold Boost Value

   64             // Chassis Cover Boost Value

   01             // Sensor Exclusion Count

   2E             // Sensor Number To Exclude From Fan Boost  

                 

   // Stepwise min Sub-Record

   02             // FSC Sub-Record Type (02h = Stepwise)

   00             // Stepwise Header ID

   25             // Stepwise Curve ID

 

   // Stepwise max Sub-Record

   02             // FSC Sub-Record Type (02h = Stepwise)

   00             // Stepwise Header ID

   2A             // Stepwise Curve ID


SR2625urlxr power supply fan always On

$
0
0

Is the power supply fan on SR2625urlxr always on even if the server is shutdown?

SR2625urlxr Embeded SROMBSASMP2 Raid Disappears

$
0
0

I noticed that my SROMBSASMP2 raid is not detected on SR2625urlxr (which was powered off for some time) and

I can only get it back if I remove the cmos battery and put it back on . It uses firmware v11.0.1-0051.

I have updated the bios to 64

S5000PAL Does not boot to Bios

$
0
0

Hi server guru's,

I have a SR2500ALLX chassis with a S5000pal board that will not boot to bios.

This is a retired server I was resurrecting for additional storage and running a virus solution.

I had just put in 5 new drives, installed new memory and successfully updated the bios to the latest release.

For a few weeks I was playing with different OS's (2012 essentials, W10 preliminary release etc) Setting up various raid configs, etc. I Had no issues at all.

In fact I was quite pleased to find the drivers not to be an issue.

It was running great.

I went to install W7 64bit everything was fine until the Os went into it's first re-boot after install, then it hung.

 

I am stuck (hung) at this screen:

---------------

Raid Controller Bios version MT30 (build Jan 05 20007)

HA-0 (Bus 4 Dev 14)

Intel raid controller SROMBSAS18E

FW package 5.1.1 -0038

 

1 logical drive found on the host adapter

1 logical drives handled by bios

---------------

 

my diagnostic lights are: green-red-green-red

 

I tried a cmos reset. no help.

I tried disconnecting various components with no luck.

 

I'm afraid the mother board is toast. But I'm up for any suggestions.

Thanks

 

Specs:

SR2500 chassis with S5000PAL

SROMBSAS18E Raid controller

5 SAS drives. NEW

16GB memory NEW

2 xeon e5410

I have some numbers on the midplane and back plane if needed.

Intel SAS Backplanes

$
0
0

Guten Tag,

ich möchte diese Diskusion eröffnen, da anscheinend viele Probleme  mit den Backplanes
AXX6DRV3GEXP und AXX4DRV3GEXP haben.
Ich leider auch.

Zum Problem: Ich habe mehrere dieser Backplans mit Expander mit unterschiedlichen Firmwareständen.
Die Firmware habe ich inzwischen gefunden:
Aktuelle Vesion ist 2.18.
Leider habe ich nur einen Asus Server , an dem ich die Backplans an einem HP 812 Raidcontroller betreibe.

Nun zu meiner Frage, gibt es eine Möglichkeit die aktuelle Firmware unter den genannten Randbedingungen auf den aktuellen Stand zu bekommen?
Für eure Hilfe bin ich Dankbar.

Fals nicht, gibt es einen hier, in der Nähe von Halle, der mir behilflich sein kann?

raid support for INTEL S5000VSA needed

$
0
0

sir

1.  i connected 500gb seagate sata hdd on sata0 port & 4tb seagate sata hdd on sata1 port on intel S5000VSA server board.

2.  Then i went to bios & enabled sata as RAID. then i saved the settings on bios.

 

but here after  i m not able to enter in to raid bios utility.

durinj system power on, i have enetered CTRL+G, CTRL+E,CTRL+X, and many more combinations to go to raid bios.

but i m not able to enter in to raid bios utility.


if i have to attach any component on board?? like GPIO cable or anything??


kindly guide me. i m struggling for past 1week.my board is S5000VSA having 3gb/s sata ports 6nos

How to install VGA Driver on Server 2012 Foundation on S1200KP?

$
0
0

Hi,

 

everytime I try to install the video driver from the S1200KP on Windows Server 2012 Foudnation it don't work, I just get an error message without any description also if I accept EULA.

 

Hopefully you can help me.

Intel ASC memory consumption

$
0
0

Hello,

 

after installation of Intel Active System Console on serverboard S2600CP and Windows Server 2012 R2 (only Hyper-V role installed), these processes start to consume lots of memory:

     platform_handler.exe

     policyservice.exe

around 2GB each, platform_handler in 2 or 3 instances, so around 6GB of memory together. After restart, everything is ok, but these processes are slowly growing up to 2GB.

I have tried ASC 6.1.14 and 7.0.20, both with the same result. After uninstall of ASC everything is ok.

 

Is there any solution? I would like to use ASC, but 6GB of memory in unacceptable.

 

Thanks.


snmpsa-6.0-1010 ia32 is died after 30-40 secs on RHEL 5.5 OS.

$
0
0

Hi,

I have a problem on RHEL 5.5 i686 OS. snmpsa-6.0-1010 ia32 does not work correctly but x86-64 works correctly. I tried 6.0 build14 [1] and 7.0 build14 but observed the same behavior.  The snmpsa(smSubagent) process is died after 30-40 secs due to huge cpu usage.

 

Output of ps -ef | grep smSubagent

red color specifies process id of smSubagent

green color specified usage of cpu

--------------------------------------------------------------------------------

root      2903     1  0 10:30 ?        00:00:00 smSubagent

root      2904 290377 10:30 ? 00:00:17 smSubagent

root      4942 24199  0 10:30 pts/1    00:00:00 watch -n1 ps -ef | grep smSubagent >> /tmp/pro_smSubagent.out && echo 'XXXXXXXX

root      4955  4942  0 10:30 pts/1    00:00:00 sh -c ps -ef | grep smSubagent >> /tmp/pro_smSubagent.out && echo 'XXXXXXXXXXXX

root      4957  4955  0 10:30 pts/1    00:00:00 grep smSubagent

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

root      2903     1  0 10:30 ?        00:00:00 smSubagent

root      2904  2903 78 10:30 ? 00:00:18 smSubagent

root      4942 24199  0 10:30 pts/1    00:00:00 watch -n1 ps -ef | grep smSubagent >> /tmp/pro_smSubagent.out && echo 'XXXXXXXX

root      4958  4942  0 10:30 pts/1    00:00:00 sh -c ps -ef | grep smSubagent >> /tmp/pro_smSubagent.out && echo 'XXXXXXXXXXXX

root      4960  4958  0 10:30 pts/1    00:00:00 grep smSubagent

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

root      2903     1  0 10:30 ?        00:00:00 smSubagent

root      2904  2903 79 10:30 ? 00:00:19 smSubagent

root      4942 24199  0 10:30 pts/1    00:00:00 watch -n1 ps -ef | grep smSubagent >> /tmp/pro_smSubagent.out && echo 'XXXXXXXX

root      4964  4942  0 10:30 pts/1    00:00:00 sh -c ps -ef | grep smSubagent >> /tmp/pro_smSubagent.out && echo 'XXXXXXXXXXXX

root      4966  4964  0 10:30 pts/1    00:00:00 grep smSubagent

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

root      2903     1  0 10:30 ?        00:00:00 smSubagent

root      2904  2903 80 10:30 ? 00:00:21 smSubagent

root      4942 24199  0 10:30 pts/1    00:00:00 watch -n1 ps -ef | grep smSubagent >> /tmp/pro_smSubagent.out && echo 'XXXXXXXX

root      4970  4942  0 10:30 pts/1    00:00:00 sh -c ps -ef | grep smSubagent >> /tmp/pro_smSubagent.out && echo 'XXXXXXXXXXXX

root      4972  4970  0 10:30 pts/1    00:00:00 grep smSubagent

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

root      2903     1  0 10:30 ?        00:00:00 smSubagent

root      2904  2903 81 10:30 ? 00:00:23 smSubagent

root      4942 24199  0 10:30 pts/1    00:00:00 watch -n1 ps -ef | grep smSubagent >> /tmp/pro_smSubagent.out && echo 'XXXXXXXX

root      4976  4942  0 10:30 pts/1    00:00:00 sh -c ps -ef | grep smSubagent >> /tmp/pro_smSubagent.out && echo 'XXXXXXXXXXXX

root      4978  4976  0 10:30 pts/1    00:00:00 grep smSubagent

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

root      2903     1  0 10:30 ?        00:00:00 smSubagent

root      2904  2903 82 10:30 ? 00:00:26 smSubagent

root      4942 24199  0 10:30 pts/1    00:00:00 watch -n1 ps -ef | grep smSubagent >> /tmp/pro_smSubagent.out && echo 'XXXXXXXX

root      4985  4942  0 10:30 pts/1    00:00:00 sh -c ps -ef | grep smSubagent >> /tmp/pro_smSubagent.out && echo 'XXXXXXXXXXXX

root      4987  4985  0 10:30 pts/1    00:00:00 grep smSubagent

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

root      4942 24199  0 10:30 pts/1    00:00:00 watch -n1 ps -ef | grep smSubagent >> /tmp/pro_smSubagent.out && echo 'XXXXXXXX

root      5350    1 0 10:31 ?        00:00:00 smSubagent

root      5351 5350 0 10:31 ?        00:00:00 smSubagent

root      5537  4942  0 10:31 pts/1    00:00:00 sh -c ps -ef | grep smSubagent >> /tmp/pro_smSubagent.out && echo 'XXXXXXXXXXXX

root      5541  5537  0 10:31 pts/1    00:00:00 grep smSubagent


[1] https://downloadcenter.intel.com/downloads/eula/23771/SNMP-Sub-Agent-Stand-alone-Intel-Server-Management-Utility?httpDown=http%3A%2F%2Fdownloadmirror.intel.com%2F23771%2Feng%2FSNMPSA_V6.0.14.zip

S1200V3RPS - Can´t install 2012r2

$
0
0

Hi, i finally just got my s1200v3rps board!

But i´m having problems installing 2012r2 from usb flash drive.

When i get to the screen to choose wich drive to install windows on it tells me that a driver is missing for either cd/dvd or hdd.

I have downloaded these drivers https://downloadcenter.intel.com/download/23257/Intel-RSTe-AHCI-SCU-Software-RAID-driver-for-Windows-

I choose these drivers during the setup  but then it once again it tells me i´m missing drivers.

 

No raid, simple ahci mode!

 

What have i missed?

 

// Erik

How to do install Win 2012 R2 in Intel Server SR1625UR

$
0
0

How can I do install Windows 2012 in server s5520UR=SR1625UR. I actualized BIOS, but I didn't need actualize Controller RAID. My controller is LSI Logic 1708. It's support this Controller:

 

MegaRAID SAS 8704ELP

MegaRAID SAS 8704EM2

MegaRAID SAS 8708ELP

MegaRAID SAS 8708EM2

MegaRAID SAS 8880EM2

MegaRAID SAS 8888ELP

 

I tried installer Windows 2008 R2 x64 Datacenter, but the system reinicialize, It's not completed operation. Occuring a error when machine is reinicialize.

I tried install Windows 7 and Windows 8 too and ocurring a same error. But i need install Windows 2012 R2. The Intel IDA don´t have the option for input installation.

 

Please help me. Thanks a lot!

ss r2000gz-gl programmatically reading the BMC chip

$
0
0

Hi,

 

I'm a developer, and I've been requested to implement a way to read the status of the redundant power supply of an Intel server in our .Net 4.0 application. Specifically a server in the r2000gz-gl series.

 

I've tried retrieving this information using WMI, to no avail.  There are WMI classes like Win32_ComputerSystem and Win32_PowerSupply which could contain such information. But when I request these on the servers they're empty.

 

I also found HP servers have specific WMI classes as discussed in topics like this one: WMI power supply

This makes me wonder if Intel servers also have specific WMI classes, but I couldn't find anything like it in the available WMI classes on the server.

 

I've installed various drivers and tools that are available from the Intel website, and among them was a tool that dumps the status of the BMC chip. I've seen that this dump contains the information I need, plus a whole lot of other information that might be usefull in the future (and a whole lot more of info that is completely not relevant to me).

 

I could write my code to start this tool, wait for it to finish, then parse the dump file and retrieve this info. But considering this tool can reach the info, I was hoping I could reach the info from my application as well. Which hopefully is a lot quicker, a lot cleaner. And preferably, if runs with WMI, makes the info retrievable from other (similar) servers in the network as well.

 

So my question is:

- Can it be done with WMI (or similar)?

- If not, can it at least be done more directly (instead of a tool > dump > parse > info route) from C# .Net4

 

Looking forward to your help.

 

Kind regards,

Koen Visser

H2216XXKR 4 node Server with S2600JF Disk Activity LED flashing Green and Status LED Amber

$
0
0

Hi,

We have  a 4 node Server (Chassis H2216XXKR) with 4 Compute Modules / Mainboard S2600JF. ESXi installed on the Servers. Every Server has 4 Drives (SSDs) as Raid 0. The OS (ESXi) is installed on a Satadom (innodisk).

 

The Servers was running since over a year without any problem.

Today one of the Servers lost one Datastore (SSD Disk (Intel 480) RAID 0) and was'nt accessible by the ESXi till i reboot the server.

After the restart the Server running normaly (all Disk accessible) - except the LED on the Drive Carrier flashing unusual.

Activity LED flashing but also the Status LED flashing amber very often. (2.5" HDD Carrier)

Why this happens ? As described above we use RAID 0 on all Drives - so no rebuild process is ongoing.

 

led.jpg

Additional Info: In the  BMC Server Health Event Log we have new enties:

bmcserverhealt.jpg 

 

Any ideas ?

 

Thanks in advance

Display issues with Intel S1200v3RPS board running Ubuntu 14.04

$
0
0

This was going to be just a standard install or so I thought...

All went well until I start the Unity desktop and it is awfully slow.

Monitor settings in Unity display settings show max option of 1280 x 1024 when the monitor is capable of much higher resolution.

Installed the Intel Graphics drivers for Linux from 01.org.

Tried multiple monitors just to be sure that the problem was not with the monitors.

Really need to resolve this issue. 

Do I need to install any monitor drivers for Samsung? The same monitors (I tried two different ones) work fine on the same version of Ubuntu on a low-end Intel motherboard.

I think the problem is specific to S1200v3RPS, the onboard graphics controller, or some such issue. Big question is: What am I missing?

Installing 2008 r2 on s5500hcv

$
0
0

Hi all,

 

I am having an issue installing 2008/r2 on a s5500hcv server using a gpt drive.

 

I have updated the mainboard firmware to 64, and the raid card as well (rs2bl040).

 

I have seperated the VD's two one 6tb, and one 2tb. The 2tb is for the backup staging, so i cannot use that

 

I have a uefi boot USB, which allows the install to load, i can select the OS, and choose the disk, it creates the partitions and then click on next, and it sits at Copying Windows files (0%) for as long as you want to leave it, It wont progress past 0%.

 

I have tried all different bios settings, and other suggestions that i have seen whilst researching the issue, all of which come to a grinding halt.

 

Can anyone suggest a way to get it to work

 

thanks

Dan


Why is Intel Deployment Assistant showing older versions?

$
0
0

I just built a new server using an S1200V3RPL board. It has the following versions:
BMC: 1.10.5637
BIOS: 01.04.0002
ME:   03.00.05.068

SDR: 1.06

 

I booted the Intel Deployment Assistant CD, version 5.2 that shipped with the board. It displays the correct current versions that I have in the BIOS setup.
I select Get System Updates, from www.intel.com (recommended), DHCP and direct connection to Internet (I'm using a wired ethernet connection).
It then shows Update Package: 1.0 30-August 2013, and clicking Show Contents displays:
IBMC Ver: 1.08.5091

SDR Ver: 1.05

BIOS Ver: 01.03.0004

ME Ver: 03.00.04.209

 

All four appear to be older versions than what I already have installed. Why is the IDA offering me these older versions? There appear to be much newer versions if I check on the web. Should I just forget about using the IDA and update manually instead?
Any advice is appreciated, thanks.

Is there intel tpm module 2.0 available for S2600GZ

Ask how to discover localhost (127.0.0.1) in Raid Web Console 2

$
0
0

I have problem to discover host in RAID web Console 2, I downloaded from https://downloadcenter.intel.com/Detail_Desc.aspx?DwnldID=18440, My server is Intel® Server Board S5520HCT are include in  valid for the product(s) listed in software requierements, but when acces to 127.0.0.1 message appear is server not found because server may be down or server not installed in the host system. Is there any configuration in Bios Setting so  I can acces the localhost.

Server crash in Idle Mode or during backup

$
0
0

If Intel server crash in Idle Mode, are there general recommended procedures to find the root cause?

 

Same question for the situation if the Intel server crash during backup.

 

Thanks for help and ideas.

How to upgrade all drives in a storage pool to expand size on MFSYS25?