плата intel s3420gpc и hdd SATA 3Tb

$
0
0

Плата intel s3420gpc (так она определила себя в биос).

Кто тестировал на совместимость с дисками SATA 3Tb?

 

лучшее, что нашел

_http://www.intel.com/support/ru/motherboards/server/s3420gp/sb/cs-030738.htm?_ga=1.11611764.1507384341.1425385462

но эта статья от

Ян 2015 Last Modified: 23

Дата создания: 06 августа 2009

и упоминается единственный диск от Hitachi


Adding drives to a raid 5 to increase storage space

$
0
0

Hello all,

I have a raid 5 array I build for a HTPC/server with aIntel® RAID Controller SRCSASBB8I. Running windows7 64bit.

 

Never had one issue glad to say except now I am runing out of storage space. I have 6,1TB Drives that yields around 4.8 TB of usable storage.

 

I thought I could simply connect another drive to the card, scan for it with the web console utility and add it. But the drive doesn't populate,show up in the console.

 

My questions,

1. It is a new drive I am adding. I didn't format it first. Maybe this needs to be done? It's the same exact drive model as all the others.

 

2. Is there any risk of corrupting the existing data on the current array when adding additional drives to increase the storage size?

 

3. In order to be able to do this was I suppose to configure the array a special way when I first initialized the virtual disk?

 

If it's best to back up all my data deleted the array and start all over because I didn't configure something to be able to add drives like this then so be it. I will do. I just would love to learn what it is that's needed so I don't find myself doing this again. 

 

Thanks in advance for any and all help!!!

impitool raw command for S2600CP FANs

$
0
0

Hi,


Please let me know ipmitool raw command for controlling S2600CP Fans?

Could you show me the examples of ipmitool raw command for controlling fans in S2600CP board?

 

Thanks in advance,

JBOD2312S2SP Power Supply Issue?

$
0
0

I have a JBOD2312S2SP Intel Raid Enclosure (Intel® Storage Systems JBOD Family) at my house and woke up to screaming fan noises.  Warning light was blinking and the console showed this:

 

ID = 206

SEQUENCE NUMBER = 164362

TIME = 29-06-2013 03:13:39

LOCALIZED MESSAGE = Controller ID:  0   Power supply cable removed on enclosure:   1      Power Supply   1

 

Note I only have one power supply so if the cable was removed not sure how it was still running.  Right after that warning received the below messages copied from the logs so the top one is the latest:


ID = 243
SEQUENCE NUMBER = 164371
TIME = 29-06-2013 03:13:44
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       3

ID = 243
SEQUENCE NUMBER = 164370
TIME = 29-06-2013 03:13:44
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       2

ID = 243
SEQUENCE NUMBER = 164369
TIME = 29-06-2013 03:13:44
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       1

ID = 243
SEQUENCE NUMBER = 164368
TIME = 29-06-2013 03:13:42
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       3

ID = 243
SEQUENCE NUMBER = 164367
TIME = 29-06-2013 03:13:42
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       2

ID = 243
SEQUENCE NUMBER = 164366
TIME = 29-06-2013 03:13:42
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       1

ID = 243
SEQUENCE NUMBER = 164365
TIME = 29-06-2013 03:13:40
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       3

ID = 243
SEQUENCE NUMBER = 164364
TIME = 29-06-2013 03:13:40
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       2

ID = 243
SEQUENCE NUMBER = 164363
TIME = 29-06-2013 03:13:40
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       1

 

Last message until 6 minutes later I powered up a computer to remove in and shutdown the system.  Pulled the power plug, put it back in, powered everything up, and it's running right now without issue.  Thoughts?

 

Edit:  As a side note, the Intel Raid Web Console shows this drive cage with 2 power supplies.  Always did.  I only have one.  So not sure if that's just how many it can hold or if it's just not intelligent enough to detect the number of drives.

 

Thanks.

 

Steve

No Intel server MB supported in ESXi 6.0

$
0
0

We have 3 x 2 year old 2600gz platforms that run ESXi 5.5.

 

After the 6.0 we verified if the platform is support just because this is our procedure. We weren't really expecting to find that no intel platform appears in the ESXi 6.0 compatibility matrix.

 

I hope this is just a delay and not the real deal.

DirectPDMapping

$
0
0

I looked at the CMDTool2 manual for the RMT3CB080 Raid controller and found the syntax to change the DirectPDMapping setting, default is off. Every time I issue the command to turn it on I get an exit code 0x1. On LSI controllers I have successfully done this in EFI. I tried MegaCLI, StorCLI and CmdTool2 in EFI and DOS, no luck. In the StorCLi utility it replies that the directpdmapping failed for set cmd Error code 3. Has anyone else seen this behavior?

 

Thanks,

Scott

ss r2000gz-gl programmatically reading the BMC chip

$
0
0

Hi,

 

I'm a developer, and I've been requested to implement a way to read the status of the redundant power supply of an Intel server in our .Net 4.0 application. Specifically a server in the r2000gz-gl series.

 

I've tried retrieving this information using WMI, to no avail.  There are WMI classes like Win32_ComputerSystem and Win32_PowerSupply which could contain such information. But when I request these on the servers they're empty.

 

I also found HP servers have specific WMI classes as discussed in topics like this one: WMI power supply

This makes me wonder if Intel servers also have specific WMI classes, but I couldn't find anything like it in the available WMI classes on the server.

 

I've installed various drivers and tools that are available from the Intel website, and among them was a tool that dumps the status of the BMC chip. I've seen that this dump contains the information I need, plus a whole lot of other information that might be usefull in the future (and a whole lot more of info that is completely not relevant to me).

 

I could write my code to start this tool, wait for it to finish, then parse the dump file and retrieve this info. But considering this tool can reach the info, I was hoping I could reach the info from my application as well. Which hopefully is a lot quicker, a lot cleaner. And preferably, if runs with WMI, makes the info retrievable from other (similar) servers in the network as well.

 

So my question is:

- Can it be done with WMI (or similar)?

- If not, can it at least be done more directly (instead of a tool > dump > parse > info route) from C# .Net4

 

Looking forward to your help.

 

Kind regards,

Koen Visser

S2600GZ MB based system attempts to boot, fans attempt to power up and system drops back to reboot and continues on and on. SYSPWDGD LED turns to green, then flashes off, a "clicking" noise ensues. System firmware is on the current release, power supplies

$
0
0

also note the ILOM will not allow the server to power up nor does the front panel.

 

Below is a snapshot of he error logs.

 

https   192.168.0.73 index.html.png


R1304WT2GS raid drivers for Microsoft Server 2012 r2 standard, Intel drivers don't work whats the solution?

$
0
0

Microsoft Server 2012 R2 Standard will not take the latest or any ESRT 2 Raid drivers when the asked at beginning of installation. I can browser to drivers and list shows compatible drivers but Windows reports they are not correct drivers. I'm stuck, cannot continue install. I called Intel support and got the usually run around i.e. case number 8001096054 and we will look into. This is a new Intel server line as of 4/1/2015, they are just released and drivers seem half baked. I also tried the RSTe raid with same result. Anybody help me or at least seen the same problem?

RS3DC0080 combined with RES3TV360 on R2224WTTYS

$
0
0

I have the intel server system R2224WTTYS with RS3DC0080 Raid card and the RES3TV360 SAS expander.  When everything is connected up I only see it linked to the expander on ports 0 - 3 rather than 0 - 7 as expected.  I have looked everything over and connected it according to the "r2000wt_systemintegration_and_serviceguide_rev1_1" documentation.  Any help would be greatly appreciated, as I have been trying to figure out the problem on my own for days.

 

Thanks in advance,

 

Doug

s5000psl will not boot, status led solid green/amber

$
0
0

I just bought a used intel s5000psl from ebay, it was just the bare board with 2 xeon 5140 and 4gb of ram. Ive got a 680w atx power supply plugged upto the board, it didnt come with a case/rack so i just made a makeshift case out of the cardboard box for testing, i found the technical product spec and found that the power button pins are 11 and 13 on the panel connector so i hooked up a button to those but when i click it when the status led is solid green nothing happens, the cpu and system fans never start up and neither does the fan on the psu.


When i plug in the psu the blue led comes on then the status led is solid green with amber blinking then its just solid green for a bout a minute, then both the green and amber are solid.

 

any info on why im not getting anything from this board would be greatly appreciated.

Can you use an DPS-830AB power supply in a 5300 BRP Case instead of the DPS-730AB?

$
0
0

Can you use an DPS-830AB power supply in a 5300 BRP Case instead of the DPS-730AB?

 

They look the same and the only difference I can find is one is 100 Watts bigger.

 

Thanks

remote (ipmi console) BIOS configuration of RS25CB080

$
0
0

I have a server in a remote location that boots from a RAID array on a RS25CB080.  I need to reconfigure this array but I only have remote IPMI console access so I cannot use the RAID BIOS Console 2 Utility.

 

Given that it's the machine's boot disk which is the array I want to reconfigure (yes, I will lose data on the array, I understand) I am figuring I cannot use the Intel RAID Web Console 2 either.

 

Is there any way to do this using a standard CLI based BIOS console that will operate over the IPMI console redirection feature of the server?

Server System SR2625URLXR Pwr Unit Status error

$
0
0

Hello, my Server System SR2625URLXR has worked about an year without any errors, but now it fails every week with error: "Pwr Unit Status reports the power unit has suffered a failure." After the fail server either restarts automatically or shuts down with BIOS beeps. Server is connected to two different UPS's, and it's power is stable.

 

In the BMC log I see follow messages:

 

Drv 5 Pres reports the device has been inserted or is present. (14:09:17)

PS1 Status reports the power supply's presence has been lost.

PS1 Status reports the power supply has recovered from the failure.

PS1 Status reports the power supply's input (AC/DC) has been regained.

Drv 4 Pres reports the device has been inserted or is present.

Drv 3 Pres reports the device has been inserted or is present.

Drv 2 Pres reports the device has been inserted or is present.

Drv 1 Pres reports the device has been inserted or is present.

BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.

Pwr Unit Redund reports full redundancy has been lost.

Pwr Unit Redund reports Redundancy Lost: Entered any non-redundant state, including Nonredundant: Insufficient Resources .

Pwr Unit Redund reports Non-redundant: Sufficient Resources from Redundant, redundancy has been lost, but the unit is still functioning with the minimum amount of resources needed for normal operation.

Drv 0 Pres reports the device has been inserted or is present.

System Event reports a PEF action has occurred - alert.

PS1 Status reports the power supply has suffered a failure.

PS1 Status reports the power supply's input (AC/DC) has been lost.

BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.

Pwr Unit Status reports that a soft power control failure has been regained.

Fan 1 Present reports the device has been inserted or is present.

Fan 6 Present reports the device has been inserted or is present.

Fan 2 Present reports the device has been inserted or is present.

Fan 3 Present reports the device has been inserted or is present.

Fan Redundancy reports Fully Redundant: Indicates that full redundancy has been regained .

Fan 5 Present reports the device has been inserted or is present.

Pwr Unit Status reports the power unit has been regained from a failure.

Pwr Unit Status reports the power unit is powered on.

Pwr Unit Status reports that a soft power control failure has been regained.

Pwr Unit Status reports the power unit has suffered a failure.

Pwr Unit Status reports the power unit is powered off or being powered down.

Button reports the power button has been pressed. (14:08:12) [<-- I pressed reset button]

Pwr Unit Status reports there has been a soft power control failure. (14:01:18)

Pwr Unit Status reports the power unit has been regained from a failure.

Pwr Unit Status reports the power unit is powered on.

Pwr Unit Status reports the power unit is powered off or being powered down.

Pwr Unit Status reports the power unit has suffered a failure. (14:01:05)

 

Yesterday I got a new error:

2012-12-10 10:38:10 Operating system bootup. Informational Open OEM Event

2012-12-10 10:38:10 OS Boot sensor 0 reports the boot from drive C has been completed. Informational Open OS Boot

2012-12-10 10:37:52 BIOS Evt Sensor reports a system boot event has occurred. Informational Open System Event

2012-12-10 10:36:22 BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on. Informational Open System Event

2012-12-10 10:33:02 Operating system bluescreen error. Informational Open OEM Event

2012-12-10 10:32:57 PCIe Fat Sensor reports a fatal PCI Express Completion Timeout error. CRITICAL Open* Critical Interrupt

2012-12-10 10:32:57 PCIe Cor Sensor reports a correctable PCI Express Link Bandwidth Changed error. Informational Open Critical Interrup

 

My question: Is this motherboard on power distribution board error?

cold reset of IPMI required after S2600WT maintenance?

$
0
0

Hi

 

After a maintenance of a couple of servers (S2600WT board), only about half of them managed to get an IP address via DHCP on IPMI afterwards.

The BIOS settings were correctly set to dynamic.

 

We tried static assignment and it worked. But for dynamic (DHCP), we needed to execute a cold reset on the IPMI to bring them back.

 

Any ideas why this happened and can be avoided for future maintenance cycles?

 

Thank you for a response, I am thankful for any ideas.

 

Best,

Maik


Intel 82574L NIC drivers for Windows 2012 R2

$
0
0

have a Supermicro SuperServer 5016I-MTHF with 2x Intel 82574L NICs. After installing Windows Server 2012 r2, the NIC is connected and working, but after a few minutes, both NICs show up as "disabled" and I cannot enable them without restarting the server. I have attempted to install drivers, but the latest PROset drivers from Intel's website say they cannot find a network adapter, and trying to manually install the drivers from Supermicro (PRO1000/Winx64/NDIS63/e1q63x64.inf) say that they are not compatible with windows.

Any help would be great, I'm at a complete loss as to how to solve this.

S2600-CP2 vmware ESXi 5.5 hangs on ACPI initialization -- Boot loop

$
0
0

Hi all,

 

I recently upgraded the firmware of a working S2600CP2 server running VMWare ESXi 5.5 build 1474528 and VMWare now gets stuck on the initialization of ACPI.  After about a minute or two of being stuck on the initialization of ACPI, the server reboots as if the reset button was pushed on the front of the server, basically resulting in a boot-loop.

 

System BIOS  - 02.02.0002

  ME Firmware  - 02.01.07.328

  BMC Firmware - 01.20 r5446

  FRUSDR       - 1.10


https://downloadcenter.intel.com/Detail_Desc.aspx?agr=Y&DwnldID=23610&keyword=S2600Cp&lang=eng

 

Here is a screenshot of the server info after the upgradepboot

 

20140219_170318.jpg

Vmware hang screen-shot

 

20140219_170047.jpg


S5000PSL fan speed

$
0
0

Recently just got this server up and running and i bought 2 stock intel LGA 771 heat sinks w/fan for it and for some reason they always run at 100%, it literally sounds like im running a shop-vac in my room.

 

The board doesn't seem to offer any way to set fan speed through the bios like desktop motherboards so i was wondering how i would be able to have them controlled based off cpu temp, or at least manually control them?

 

I have tried modifying the SL_48.SDR file so that normal fan speed for all chassis is at 50% and this didn't seem to do anything. Oh also im not using a chassis , its just the bare board for now.

 

any help would be much appreciated, thank you.

intel s5000vsa sata board raid configure support needed

$
0
0

i m planning to install two sata hard drives of 500gb each.

i want to configure raid 0 on two hard drives.

i want to install win7 64bit .

 

kindly any one guide me to do the above task.

 

i set SATA as RAID.

but i m not able to enter in to RAid Menu.

Interpretation of POST LED displays missing in documentation.

$
0
0

After some initial hiccups, I was able to get the Intel motherboard to at least power up. Now it does not start the boot process. I tried to understand the LED displays which explain problems encountered during Power-On-Self-Test(POST). I get the following code: 00101011. That is Amber LED No. 5 is on and so are Green LEDs no. 0, 1 and 3. However, the mother board product technical specification document, does not list an explanation for this code. Need to know what is wrong with the motherboard or which component is faulty. To make sure that I was not getting the bits wrong, I tried to boot without the RAM and the diagnostic LED did show the applicable POST code.