intel RST raid 1 preserve data greyed out

$
0
0

Hello, at the moment i'm bit frustrated, my situation looks like this:

 

1. i had intel RST raid 1 (seagate 1TB constelletion x 2 ) setup (in bios set Raid and intel RST), raid 1 was working, but both DRIVES started to fail (realocated sector count and other smart errors).

 

2. I bought new 4TB seagate raid disks

 

3. I removed one old 1Tb hard drive and put in new 4TB hard drive and marked as spare, raid rebuilded with new and old drive

 

4. i removed 1Tb hard drive and resseted 4Tb drive from CTRL-I as non raid drive

 

5. i streched 4Tb raid drive to maximum in disk management (because it is MBR-NTFS not GPT it's not bigger than 2TB...), for now 2Tb enough later i will reinstall server to 4TB and GPT, but i dont know how to proceed...

 

6. i updated server firmware to latest (intel server board 1200bt), and the installed latest intel RST software.

 

what i wan't to accomplish is create RAID from intel RST raid 1 preserving data

 

intel_rst.JPG

but how You see this option is greyed out...

 

And here is screenshot of disk management (i deleted other backups disks to better understand):

disk_management.JPG

if anyone would advise me, what to do? How to build raid1 with preserving data?

 

Should i backup everthing and reinstall windows server with GPT partitions, and then how to restore everything as it was?

 

And here is screenshot from CTRL-I (it was taken before i upgraded intel RST software)

 

20150222_222626 (Medium).jpg

 

Thank You in advance...


SR1560SF and ESXi 5.5

$
0
0

Hello everyone,

 

I've been searching the web to no avail, I wanted to know if anyone is running ESXi 5.5 on this server.  I have the opportunity to purchase some of these at a very reasonable price.

 

Thank you

S2600CO4 with (2) E5-2643 not reporting processor thermal margin

$
0
0

I have two S2600CO4 boards and neither of them reports processor thermal margin sensors.

 

P1 Therm Margin  | na     | degrees C  | na| na    | na    | na    | na    | na    | na  
P2 Therm Margin  | na     | degrees C  | na| na    | na    | na    | na    | na    | na  
P1 Therm Ctrl %  | na     | percent| na| na    | na    | na    | 30.000| 50.000| na  
P2 Therm Ctrl %  | na     | percent| na| na    | na    | na    | 30.000| 50.000| na  

 

Nor do them report DIMM thermal margins

DIMM Thrm Mrgn 1 | na     | degrees C  | na| na    | na    | na    | 5.000 | 10.000| na  
DIMM Thrm Mrgn 2 | na     | degrees C  | na| na    | na    | na    | 5.000 | 10.000| na  
DIMM Thrm Mrgn 3 | na     | degrees C  | na| na    | na    | na    | 5.000 | 10.000| na  
DIMM Thrm Mrgn 4 | na     | degrees C  | na| na    | na    | na    | 5.000 | 10.000| na  

 

The end result is that all the fans in the system run at full RPM.  The system itself is fully functional otherwise.  BIOS is at version 2.04.0003, BMC is at 1.22.6890, ME is at 02.01.07.328 and FRU/SDR is at 1.12.  Update was done from the latest EFI package for the board.  The system event log has entries noting the processor thermal margin sensor failures.

 

I have reflashed all the images individually.  I have verified that the SDR table is getting updated -- I slightly changed the name of the processor thermal sensors and verified that the new name showed up in the the RMM sensor table as well as an "ipmitool sensor".

 

The system is in a non-Intel chassis.  Fans are connected for system fan 1-3, rear fan, and cpu fan 1 and 2.  When updating the FRU/SDR records, the update script properly identifies it as an "other" chassis and prompts me for the various fan connections.

 

I'm looking for suggestions on what I might be missing here.

Fault resilient boot

$
0
0

What does the  FBR feature in Intel  server board do ?

 

What is the use ?

Blinking Amber indication in front panel of JFQJR Server , what does it indicate?

$
0
0

Blinking Amber indication in front panel of JFQJR Server , what does it indicate?

  I've checked  bios for  memory error but it is fine , there is no error in event log.

Intel rmm3 problem

$
0
0

Hi.

 

I have Intel rmm3 installed on one of my servers

 

Smash CLP Version :SMASH 1.0.0/CLP 1.09

 

Somehow web is not working (page loading), but i do have ssh access. Is it possible to reboot server from console?

 

Thank you.

S2600GZ undocumented LED diagnostic code?

$
0
0

We have four identical servers based on the S2600GZ board, three of which are running with the POST Code Diagnostic LEDs lit in the combination 1101(amber)0100(green), while the fourth one has all of them off.

 

That combination (D4h) is undocumented in the Technical Product Specification doc for the board, and I wonder what it could mean...  all three servers show up as healthy in the RMM4 web interface.

 

Thank you.

I have a server with a 1200 V3 series server board. The RAID controller is showing one of the drives failed. Replaced the drive and mother board but the problem remains.

$
0
0

In this case slot 0. I have replaced the drive and it goes through the rebuild then shows failed again. To continue to troubleshooting I replaced the mother board and rebuild the array. When I left the server the array was rebuilding. I came back and the array is showing the drive in slot 0 failed again. I am seeing the following message in the logs in the Intel RAID Web Consile 2. " ID 113, Error Level [Information, 0] Description Controller ID:0 Unexpected sense: PD = 0-No additional sense information, CDB = 0x35 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00, Sense 0x70 0x00 0x0b 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x80 0x00 0x02. Any idea what is wrong. Like I said I replaced the drive and then the motherboard. I am not sure what is going on. Note that the first drive I pulled passed a disk diagnostic with flying colors. Thank in advanced for any insight to this issue. I also set up email reporting and got this message from the server.

 

Controller ID: 0  VD is now DEGRADED   VD 

    0

Event ID:251

Generated On: Fri Mar 13 19:33:39 MDT 2015

 

System Details---

Server IP:169.254.180.143

OS name:Windows

OS Version:unknown

Driver Name:LSI MegaSR RAID5

Driver Version:16.01.2014.0318

 

Image Details---

BIOS Version : A.11.02151531I

 

Thanks,

TSC


Adding drives to a raid 5 to increase storage space

$
0
0

Hello all,

I have a raid 5 array I build for a HTPC/server with aIntel® RAID Controller SRCSASBB8I. Running windows7 64bit.

 

Never had one issue glad to say except now I am runing out of storage space. I have 6,1TB Drives that yields around 4.8 TB of usable storage.

 

I thought I could simply connect another drive to the card, scan for it with the web console utility and add it. But the drive doesn't populate,show up in the console.

 

My questions,

1. It is a new drive I am adding. I didn't format it first. Maybe this needs to be done? It's the same exact drive model as all the others.

 

2. Is there any risk of corrupting the existing data on the current array when adding additional drives to increase the storage size?

 

3. In order to be able to do this was I suppose to configure the array a special way when I first initialized the virtual disk?

 

If it's best to back up all my data deleted the array and start all over because I didn't configure something to be able to add drives like this then so be it. I will do. I just would love to learn what it is that's needed so I don't find myself doing this again. 

 

Thanks in advance for any and all help!!!

RAID warning

$
0
0

Ignorance is a bliss sometimes, but once one becomes aware, one wants to know what it might be or how to react.

So, the RAID Web console is sending messages like these from time to time.

 

Controller ID: 0 Patrol Read aborted on PD: -:-:6

Event ID:445

Generated On: Sat Mar 14 03:00:00 EET 2015

 

System Details---

Server IP:10.0.1.4

OS name:Windows

OS Version:version

Driver Name:megasas.sys

Driver Version:6.600.21.08

 

Image Details---

BIOS Version : 6.20.04.1_4.16.08.00_0x06090702

Firmware Package Version: 24.6.0-0036

Firmware Version : 4.260.00-4046

 

Controller

ARK | Intel® RAID Controller RS3DC080
System

ARK | Intel® Server System R2308GZ4GC

Problem Intel Vernonia S5000XVN + MSI GTX 750

$
0
0

Just installed new graphic card to my worksation on s5000xvm, i repleced my old radeon 6450 hd with geforce MSI gtx 750 3gbddr5, the problem looks like that - after installation of new card i start a workstation i got bios beep - sounds ok, but no signal on monitor, then i got windows startup sound so it still sound ok but still no signal on display monitor, so it looks like whole worstation is working fine just a gpu gives no signal using d sub, ive chcecked my PCIE slot - it looks clean, whole mainboard looks ok - no dirt, no burnings, no sign of any damage, after i put back my old radeon ( on the same PCIE slot that didnt work with new card, same monitor, same cable ) everything works fine ( im just using it so it really works fine) so i guess PCI slot is ok, and also workstatnion i in use for like 12h every day - 3ds max, internet browsing, some gameing even - totally no problems - starts fine, no hang ups, no crashes, no problems with high temperatures i really keep it in good condition, and ofcourse when i put new card in ive clean pcie with air duster just in case - my full configuration looks like that :

Intel Vernonia S5000XVN

2x quad core Xeon e 5420

12 gb Fb dimm ( 6x2gb ddr 2)

2x hdd

power supply - delta electronics 670W

monitor - Acer V196hql

im using vga(dsub) cable

old graphic card - ati radeon hd 6450 - works fine

new graphic card - MSI Global N750-2GD5/OC - totally no signal, with workstation sounds like working correctly ( sound of windows startup )

bios - 03/26/07

Any ideas>>>?i really really really wanna new gpu

Rapid Storage Technology enterprise - Windows isn't recognizing the full RAID 5 drive space

$
0
0

I just setup my first server using an S1200v3RLP Intel board and Windows 2012 R2.  I configured the BIOS to see my 5 2TB drives as Raid 5 using Rapid Storage Technology Enterprise (RSTe).  After installing the driver during the OS install and loading the application, I waited about 2 days for the raid array to complete the initialization process.  Now, windows is still saying that I only have 2TB, not the full 7TB. Do I need to create the volume again in Windows, similar to what I did when I first setup the RAID in EFI?  If so, will this destroy my current info (OS + windows updates).  I've read the Windows OS user guide for RSTe, but I'd have a little more comfort if I had some feedback from the community. 

s3420gp problem with rdimm not supported??

$
0
0

Hello Intel hello all!!

 

just i upgrade my systemboard s3420gplc from i3 560 to xeon x3470 and works fine

with i3 560 and xeon x3470 i had 2x2gb uddims a1 b1 slot working fine!!

i bought 4x rdimm 4gb samsung M393B5170D1Z-CH9 from support list in memory compatibility for s3420gplc

all rdimms faild(beeps)  and the serverboard has errors.

 

000x0x00 memory test error. memory failed hardware bist

i upgrade the bios to latest + bmc + sdr..


i have 2 sas controllers and when i disconnect them the problem exists.


can any one help me??

FRUSDR update on S2600CW2 with P4304XXMFEN fails to detect chassis

$
0
0

Hello,

 

Building first server with a S2600CW2 and P4304XXMFEN chassis.

 

When running FRUSDR 1.07 it says it cannot auto detect chassis.

 

Is this normal for the above combo? Tried with previous FRUSDR 1.05 with same result.

 

Should this combo be detected?

 

Regards,

 

GT

raw ipmi command to retrieve NIC 1 MAC address on S2600GZ

$
0
0

Hi there,

 

what is the right approach to retrieve the NIC 1 MAC address (for OS usage) via IPMI?

 

NOTE: I am assuming the system is powered off and that a DHCP server assigned an IP address to the BMC LAN channel 1.

 

The S2600GZ technical product specification section 6.10.3.2.3 highlights the convention used to assign MAC address so conceptually one could calculate it from the BMC LAN channel 1 MAC address (by subtracting 4) but that seems brittle so I am looking for the (raw) IPMI command to provide that info directly!?

 

Other vendors implemented vendor-specific IPMI commands but I can't seem to find the doc that would cover an S2600GZ board..

 

Thanks & cheerio, Harry.


s1200bt server won't start - one long beep on powerup

$
0
0

I moved the server 6 inches and now it wont start. Just one long beep and nothing else. no display either.

the diagnostic leds show 0 0 0 X 0 X 0 X

the manual does not cover the led combo above. any thoughts?

Tried unplugging and re-plugging the power cord, removing all power and

connections from M/B, reseating all components, same 1 long beep and nothing else.

Please help

Intel S5000XVN red leds+power led blinking+Monitor not displaying

$
0
0

Hello.I got a problem with Intel S5000XVN..2 days ago i've tried to power on my pc and the monitor wasn't displanying anythig..the led from monitor was turning orange from green,then i've looked in the computer and i saw the power led was green and blinking and the leds next to it was red...i will insert a video for you guys to see what it is about and tell me from what can it be...i've tried to disconnect all peripherals/clean dust from ram memory but nothing...i've tried to power it on just with 1 memory stick still nothing.

W2600CR2 NVMe SSD (non-Intel) boot support

$
0
0

We have a workstation with a W2600CR2 board, dual E5-2687W v2 Xeons, and a new NVMe PCIe X4 SSD (non-Intel).  The SSD has booted successfully in other systems, but I cannot get it to be a bootable device on the W2600CR2, even after updating the BIOS of the board, and trying all possible BIOS options.  After installing Windows on it, the EFI shell sees the drive as blk, but no fs. 

 

Help!

PCIe MPS(Max Payload Size) in intel server

$
0
0

Hi, everyone

 

My server has a nic card of which PCIe MPS(max payload size) capability is 1024 bytes.

However, the MPS of the nic card negotiated is 128 bytes.

We search for the reason and we found that the MPS capability of the intel PCIe bridge connected with our nic is 128 bytes.

Our OS is linux.

Please let me know if there is any method for modifing the MPS of our nic?

If the MPS of the bridge is 128bytes, is the MPS of the nic connected to it alway under 128bytes?

 

Thanks in advnace.

J.Hwan Kim

SE7520BD2 DDR2-400 Blue Screen on Reeboot or Shutdown

$
0
0

Hello!

 

I have a blue screen crashes strictly on reboot or shut down my computer.

Blue screen appears immediately after the screen "Shutdown"

*** Hardware Malfunction

Call your hardware vendor for support

*** The system has halted ***

This is old server. I decided to use him as reserved copy server.

Buy RAID controller LSI SAS 9240-8i and 8 HDD Seagate Constellation SAS ST1000NM0001.

 

Hardware configuration:

Motherboard Intel server board SE7520BD2 DDR2-400.

RAID controller LSI SAS 9240-8i.

8 HDD Seagate Constellation SAS ST1000NM0001.

Last BIOS vervion. 8 GB RAM.

 

I tried to install Linux Centos 6.6 x64 - linux works without fails, without error messages in logs.

I tried to install Windows 7 SP1 x64 VL, Windows 2008R2 x64 Standart, Windows 2012 - on all OS gets blue screeen on reboot/shutdown.

I tried to disconnect RAID controller LSI SAS 9240-8i and install Windows 7 on old IDE HDD - also I have blue screen.

 

At the time the blue screen in the system log an error:

 

log Name:   System

source:      Microsoft-Windows-Kernel-Processor-Power

Date:          25.03.2015 17:17:27

event ID:   6

task Category:(6)

Level:       Error

Keywords:

User:  system

Computer:     User-PC

Description:

Some processor power management features in the performance state have been disabled due to a known issue with the firmware. Learn about the available firmware updates from the manufacturer of your computer.

Xml development:

<Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">

  <System>

    <Provider Name="Microsoft-Windows-Kernel-Processor-Power" Guid="{0F67E49F-FE51-4E9F-B490-6F2948CC6027}" />

    <EventID>6</EventID>

    <Version>0</Version>

    <Level>2</Level>

    <Task>6</Task>

    <Opcode>0</Opcode>

    <Keywords>0x8000000000000000</Keywords>

    <TimeCreated SystemTime="2015-03-25T14:17:27.375000000Z" />

    <EventRecordID>910</EventRecordID>

    <Correlation />

    <Execution ProcessID="4" ThreadID="60" />

    <Channel>System</Channel>

    <Computer>User-PC</Computer>

    <Security UserID="S-1-5-18" />

  </System>

  <EventData>

  </EventData>

</Event>

Viewing all 3923 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>