Receiving event log error for PS on S1200RP server

$
0
0

When I looked at the server event log in the RMM I saw events for the power supply redundancy. In the sensor readings it shows yellow with a warning and a reading of 0x0001. The event log shows the following entries:

PS1 StatusPower Supplyreports a predictive failure has been detected for the power supply - Deasserted

 

PS2 StatusPower Supplyreports a predictive failure has been detected for the power supply - Deasserted

 

Pwr Unit RedundPower Unitreports redundancy has been lost, but the unit is still functioning with the minimum amount of resources needed for normal operation - Asserted

 

Pwr Unit RedundPower Unitreports redundancy has been lost - Asserted

 

Is this something I need to be concerned with? I have not seen any other indications of failure. Are one or both of the Power Supplies beginning to fail?

 

Thanks,

Mike


Invalid Dimm population @ Intel S2600CP Server Board

$
0
0

Hi, good day. I'm new to building server system.

 

Currently I'm installing a server by using the below parts:

 

- Intel S2600CP Server Board, (MM: 916040; Batch: CNQS44E5K1; Version: G41269-505)
- 2 x Intel XEON E5-2620V2 processors
- 8 x Kingston 8GB DDR3-1600 ECC KVR16LN11/8

 

However, I keep getting the error message when system boot up -- Invalid dimm population.

 

I try to install 4units of ram at slot A1, A2 & E1, E2; or even just A1 and E1 also fail to boot up. Can anyone help to resolve this issue?

Intel updates in the form of catalog to use with WSUS

$
0
0

I would like to know if Intel provides the product updates in the form of catalog to use with WSUS and distribute the updates. Like the one provided by DELL, IBM and HP for their product security updates.

S2400SC hangs at copyright screen

$
0
0

I have a new P4000M series chassis, with an S2400SC board.  At first, it wouldn't boot at all and gave no indication why.  I determined that the BIOS needed to be updated to support the E5-2407 V2 processors.  I was able to find a pair of earlier processors, and successfully update the BIOS, BMC etc. via EFI.  Now the server boots to the copyright screen, and hangs there with a flashing cursor in the lower left of the screen.  I have tried BIOS & BMC recovery, CMOS clear, old and new processors - still not working.  Diagnostic LEDs stop at ABh (DXE Setup Start).  Any ideas?

 

Thank you,

 

Greg

IPD since 1994

Intel® Server Board S5500WB 12V

$
0
0

Hi,

 

Recently I picked up a used board Intel® Server Board S5500WB, little did I knew this board as 12V version. I thought its going to be another board with standard power connector, I could use a high power ATX PSU to supply it. 

 

Now how can I power up the motherboard ? I have a PSU which has dual 12V output. Is that all needed to start the board ?

 

http://manuals.ts.fujitsu.com/file/9269/cx120s1-d3052-intel-tps-en.pdf

 

I wanted this system with dual xenon and 16GB RAM for video encoding.

 

Thank you for your help.

 

regards,

Dwija

Intel s1200v3 comparison

$
0
0

Greetings Everyone, my first post here and probably many more in the future

 

I'am in the process of building a computer for audio purpose only. I have been searching for days, probably a month but unable to find definite answers, I want to be 100% sure if I'am buying the correct compatible hardware.

 

I believe some of you might be kind enough (if i may add, highly skilled experts with immense knowledge of computers) to help me out with this dilemma & queries which bog my mind.

 

 

Mobo Intel S1200V3 motherboard

Intel Haswell Xeon E3-1230L v3 CPU

the ram would be 2x2GB Apacer ECC DDR3-1066 RAM, CL7, unbuffered, industrial series (extended temp range from -45 to +85

 

'am confused about the MOBO, there are 4 versions in the intel s1200v3 family, RPL, RPO, RPM, RPS. Please note this will be a dedicated PC for playing audio only.

I have been asked to choose the one with minimum features, which one would that be?

 

thank you in advance and best regards,

Ben

 

p.s. OS would be windows server 2012 r2.

Bug in master.cfg in S2400SC firmware update

$
0
0

Please confirm the following bug in latest "Intel® Server Board S2400SC Firmware Update Package for EFI" package.

 

Details:

 

Intel® Server Board S2400SC Firmware Update Package for EFI

version: 02.03.0003

release date: 05/21/2014

link: Intel® Download Center

 

in FRUSDR 1.10 utility update package there is a bug that prevents manual setting of Power system unit type when auto detecting fails.

 

in line 181 in MASTER.CFG

FOUND "PS1_FRU" "PS1_NO_FRU" 

should change to                   

FOUND "PS1_FRU" "NO_PS1_FRU"

 

and in line 246 in the same file

FOUND "PS2_FRU" "PS2_NO_FRU"

should change to

FOUND "PS2_FRU" "NO_PS2_FRU"

 

 

I also checked that this problem also affects at lease one  previous update package FRUSDR 1.09

This problem affected my "Intel® Server System R2312SC2SHGR"

 

thank you in advance

 

bb

RAID Problem - server DOWN

$
0
0

Hello,
I have a problemand ask foryouradvice.
I have 2identicalserverssr2612urwithRAIDSROMBSASMR. Onenowcollapsed.When Igot to him- allRAIDarrayglowedorange.Theserverwas notpossible tolog in remotelyandevenlocalcontrolwas notpossible (not VGAoutputandkeyboarddid not respond). Ihad toturn off theserverhard-boiled.
Newstartserver.MostRAIDpassedwithin a few minutesin the greenstate.Itisonerepaireda fewhours, it is nowalsoin the greenstate.

LoginRAIDWebConsole2aredamaged(cyclically repeated). Butat1 AMistriggeredperiodiccontrol (Patrol Read).Atabout 2AMcamethe command "ID = 29LocalizedMESSAGE =ControllerID: 0Hibernatecommandreceivedfromhost"Whatitmeansaodkudcommandcame, I do not know. I neverthiscommandin the logoseen.Atabout 3AMserverstoppedcommunicating.

questions:
1) How do I knowwhatandwhy itissuedthe command "Hibernate commandreceivedfromhost"
2) It can befound, whynot to turn offfrom point 1?
3) How to getmore detailedlogsfromRAIDcontrollers?

Thankyou very much


Please excusemyEnglish.


Import foreign configuration failed

$
0
0

Hi,

i try situation for disaster recovery.

I have 2 similar servers with SROMBSASMR. When I try tu test remove 1 drive from server A position 1 and give it back to the same place (server A position 1) --> I become "Foreign Unconfigured bad". Then I change it to "Foreign Unconfigured Good". When i try to import Foreign configuration over Intel RAID Web console 2 i become "Import Failed"

When i try use CmdTool2

CmdTool2 -CfgForeign -Import -aALL

Failed to import foreign configuration on controller 0.

FW error description:

Foreign drives cannot be imported, as they do not form a complete configuration.

Exit Code: 0x3b

 

CmdTool2 -CfgForeign -Preview -aALL

 

Foreign configuration on controller 0(After import):

Number of DISK GROUPS: 4

 

DISK GROUP: 0

Number of Spans: 1

SPAN: 0

Virtual Drive Information:

Virtual Drive: 0 (Target Id: 0)

Name                :

RAID Level          : Primary-1, Secondary-0, RAID Level Qualifier-0

Size                : 1.817 TB

Sector Size         : 512

Mirror Data         : 1.817 TB

State               : Optimal

Strip Size          : 256 KB

Number Of Drives    : 2

Span Depth          : 1

Default Cache Policy: WriteThrough, ReadAdaptive, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteThrough, ReadAdaptive, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy   : Disk's Default

Encryption Type     : None

Is VD Cached: No

Physical Disk Information:

Physical Disk: 0

Enclosure Device ID: 10

Slot Number: 1

Drive's position: DiskGroup: 0, Span: 0, Arm: 0

Enclosure position: 1

Device Id: 12

WWN:

Sequence Number: 2

Media Error Count: 0

Other Error Count: 0

Predictive Failure Count: 0

Last Predictive Failure Event Seq Number: 0

PD Type: SAS

 

Raw Size: 1.819 TB [0xe8e088b0 Sectors]

Non Coerced Size: 1.818 TB [0xe8d088b0 Sectors]

Coerced Size: 1.817 TB [0xe8b6d000 Sectors]

Sector Size:  0

Firmware state: Online, Spun Up

Device Firmware Level: 0006

Shield Counter: 0

Successful diagnostics completion on :  N/A

SAS Address(0): 0x5000c5003c64511d

SAS Address(1): 0x0

Connected Port Number: 0(path0)

Inquiry Data: SEAGATE ST32000444SS    00069WM6REZV

FDE Capable: Not Capable

FDE Enable: Disable

Secured: Unsecured

Locked: Unlocked

Needs EKM Attention: No

Foreign State: None

Device Speed: 6.0Gb/s

Link Speed: 3.0Gb/s

Media Type: Hard Disk Device

Drive Temperature :39C (102.20 F)

PI Eligibility:  No

Drive is formatted for PI information:  No

PI: No PI

Port-0 :

Port status: Active

Port's Linkspeed: 3.0Gb/s

Port-1 :

Port status: Active

Port's Linkspeed: Unknown

Drive has flagged a S.M.A.R.T alert : No

 

 

 

Physical Disk: 1

Enclosure Device ID: 10

Slot Number: 4

Drive's position: DiskGroup: 0, Span: 0, Arm: 1

Enclosure position: 1

Device Id: 14

WWN:

Sequence Number: 2

Media Error Count: 0

Other Error Count: 0

Predictive Failure Count: 0

Last Predictive Failure Event Seq Number: 0

PD Type: SAS

 

Raw Size: 1.819 TB [0xe8e088b0 Sectors]

Non Coerced Size: 1.818 TB [0xe8d088b0 Sectors]

Coerced Size: 1.817 TB [0xe8b6d000 Sectors]

Sector Size:  0

Firmware state: Online, Spun Up

Device Firmware Level: 0006

Shield Counter: 0

Successful diagnostics completion on :  N/A

SAS Address(0): 0x5000c5003c7ccb4d

SAS Address(1): 0x0

Connected Port Number: 0(path0)

Inquiry Data: SEAGATE ST32000444SS 00069WM7BAYV

FDE Capable: Not Capable

FDE Enable: Disable

Secured: Unsecured

Locked: Unlocked

Needs EKM Attention: No

Foreign State: None

Device Speed: 6.0Gb/s

Link Speed: 3.0Gb/s

Media Type: Hard Disk Device

Drive Temperature :40C (104.00 F)

PI Eligibility:  No

Drive is formatted for PI information:  No

PI: No PI

Port-0 :

Port status: Active

Port's Linkspeed: 3.0Gb/s

Port-1 :

Port status: Active

Port's Linkspeed: Unknown

Drive has flagged a S.M.A.R.T alert : No

 

 

 

DISK GROUP: 1

Number of Spans: 1

SPAN: 0

Virtual Drive Information:

Virtual Drive: 0 (Target Id: 2)

Name                :

RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0

Size                : 1.817 TB

Sector Size         : 512

Parity Size         : 0

State               : Optimal

Strip Size          : 256 KB

Number Of Drives    : 1

Span Depth          : 1

Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy   : Disabled

Encryption Type     : None

Is VD Cached: No

Physical Disk Information:

Physical Disk: 0

Enclosure Device ID: 10

Slot Number: 10

Drive's position: DiskGroup: 1, Span: 0, Arm: 0

Enclosure position: 1

Device Id: 8

WWN:

Sequence Number: 2

Media Error Count: 0

Other Error Count: 0

Predictive Failure Count: 0

Last Predictive Failure Event Seq Number: 0

PD Type: SAS

 

Raw Size: 1.819 TB [0xe8e088b0 Sectors]

Non Coerced Size: 1.818 TB [0xe8d088b0 Sectors]

Coerced Size: 1.817 TB [0xe8b6d000 Sectors]

Sector Size:  0

Firmware state: Online, Spun Up

Device Firmware Level: 0006

Shield Counter: 0

Successful diagnostics completion on :  N/A

SAS Address(0): 0x5000c50025b35c39

SAS Address(1): 0x0

Connected Port Number: 0(path0)

Inquiry Data: SEAGATE ST32000444SS 00069WM2DX22

FDE Capable: Not Capable

FDE Enable: Disable

Secured: Unsecured

Locked: Unlocked

Needs EKM Attention: No

Foreign State: None

Device Speed: 6.0Gb/s

Link Speed: 3.0Gb/s

Media Type: Hard Disk Device

Drive Temperature :40C (104.00 F)

PI Eligibility:  No

Drive is formatted for PI information:  No

PI: No PI

Port-0 :

Port status: Active

Port's Linkspeed: 3.0Gb/s

Port-1 :

Port status: Active

Port's Linkspeed: Unknown

Drive has flagged a S.M.A.R.T alert : No

 

 

 

DISK GROUP: 2

Number of Spans: 1

SPAN: 0

Virtual Drive Information:

Virtual Drive: 0 (Target Id: 1)

Name                :

RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0

Size                : 1.817 TB

Sector Size         : 512

Parity Size         : 0

State               : Optimal

Strip Size          : 256 KB

Number Of Drives    : 1

Span Depth          : 1

Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy   : Disabled

Encryption Type     : None

Is VD Cached: No

Physical Disk Information:

Physical Disk: 0

Enclosure Device ID: 10

Slot Number: 12

Drive's position: DiskGroup: 2, Span: 0, Arm: 0

Enclosure position: 1

Device Id: 9

WWN:

Sequence Number: 5

Media Error Count: 0

Other Error Count: 0

Predictive Failure Count: 0

Last Predictive Failure Event Seq Number: 0

PD Type: SAS

 

Raw Size: 1.819 TB [0xe8e088b0 Sectors]

Non Coerced Size: 1.818 TB [0xe8d088b0 Sectors]

Coerced Size: 1.817 TB [0xe8b6d000 Sectors]

Sector Size:  0

Firmware state: Online, Spun Up

Device Firmware Level: 0006

Shield Counter: 0

Successful diagnostics completion on :  N/A

SAS Address(0): 0x5000c50025b35a85

SAS Address(1): 0x0

Connected Port Number: 0(path0)

Inquiry Data: SEAGATE ST32000444SS 00069WM2EFPV

FDE Capable: Not Capable

FDE Enable: Disable

Secured: Unsecured

Locked: Unlocked

Needs EKM Attention: No

Foreign State: None

Device Speed: 6.0Gb/s

Link Speed: 3.0Gb/s

Media Type: Hard Disk Device

Drive Temperature :38C (100.40 F)

PI Eligibility:  No

Drive is formatted for PI information:  No

PI: No PI

Port-0 :

Port status: Active

Port's Linkspeed: 3.0Gb/s

Port-1 :

Port status: Active

Port's Linkspeed: Unknown

Drive has flagged a S.M.A.R.T alert : No

 

 

 

DISK GROUP: 3

Number of Spans: 1

SPAN: 0

Virtual Drive Information:

Virtual Drive: 0 (Target Id: 255)

Name                :

RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0

Size                : 1.817 TB

Sector Size         : 512

Parity Size         : 0

State               : Offline

Strip Size          : 256 KB

Number Of Drives    : 1

Span Depth          : 1

Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy   : Disabled

Encryption Type     : None

Is VD Cached: No

Physical Disk Information:

Physical Disk: 0

Enclosure Device ID: 10

Slot Number: 6

Enclosure position: 1

Device Id: 17

WWN:

Sequence Number: 14

Media Error Count: 0

Other Error Count: 0

Predictive Failure Count: 0

Last Predictive Failure Event Seq Number: 0

PD Type: SAS

 

Raw Size: 1.819 TB [0xe8e088b0 Sectors]

Non Coerced Size: 1.818 TB [0xe8d088b0 Sectors]

Coerced Size: 1.817 TB [0xe8b6d000 Sectors]

Sector Size:  0

Firmware state: Offline

Device Firmware Level: 0004

Shield Counter: 0

Successful diagnostics completion on :  N/A

SAS Address(0): 0x5000c500763b4499

SAS Address(1): 0x0

Connected Port Number: 0(path0)

Inquiry Data: SEAGATE ST2000NM0023 0004S1X05S0X

FDE Capable: Not Capable

FDE Enable: Disable

Secured: Unsecured

Locked: Unlocked

Needs EKM Attention: No

Foreign State: None

Device Speed: 6.0Gb/s

Link Speed: 3.0Gb/s

Media Type: Hard Disk Device

Drive Temperature :40C (104.00 F)

PI Eligibility:  No

Drive is formatted for PI information:  No

PI: No PI

Port-0 :

Port status: Active

Port's Linkspeed: 3.0Gb/s

Port-1 :

Port status: Active

Port's Linkspeed: Unknown

Drive has flagged a S.M.A.R.T alert : No

Exit Code: 0x00

Thank You for your help.

Intel Modular Server Battery Failure

$
0
0

We are getting repeated battery warning messages from an Intel Modular Server (see below).  We are looking for a replacement battery that we can afford (I'm told Intel no longer supports this platform.)  My question is, 1) What will happen if the battery fails or malfunctions before we can substitute a working battery? 2) What is a compatible substitute for this part?

 

Thank you.

 

_____________________________________________________________________________________

Event Id: 1953
  Policy Id: 3400
 
  Severity: Warning
  Type: Storage
  Component: Storage Controller 2
  User Name: System
 
  Description: The write policy of virtual drive {AliasName} has been
  changed from write-through to write-back
 
  Probable Cause: This event is caused by the battery being in a less than
  optimal state. For example, it is below threshold due to discharge during
  reconditioning, or the battery is malfunctioning.
 
  Corrective Action: Check the battery to see if it is malfunctioning. If
  so, replace the battery.
 
  Extra Data:
  s:144:"0000000000000000000000000000000000000000000000000000000000000000|PSev:2|Time:20140831012545.000000+000|SysName:2000001517C778E1|Seq:1878|Ctrlr:0";

Raid controller rs3wc080 won't start

$
0
0

I Purchased a rs3wc080 to be able to ad a lot of sas disks to my pc. It is a regular machine with Asus P9x79 mobo and i7 cpu running win7 pro x64.

The card worked out of the box, but during copy jobs of some size (30+ minutes) it would cause BSOD. After a while it would also occationally fail to start with windows, with error code 10 "this device cannot start".

 

I have flashed the card and the mobo with the latest firmware and updated win drivers but the problem was just getting worse. I've also removed the card, tried it with no disks attached, down stepped the pcie slot to gen 1 and 2. Downgraded firmware. Upgraded again. Using both console and efi. All with success, but without solving the problem. Currently the virtual disks are presented to the mobo bios, and all is fine in the raid controller bios. But in windows the disks don't show, and in device manager the card shows up with error 10 cannot start.

I even tested the card in my old pc, which has the older x48 chipset, and all worked fine even under hard load with robocopy. Since it worked in my old machine, which is running win7, I figured maybe my os installation was to blame. So I reinstalled windows, downloaded the latest driver for the card from Intel, and... Error 10...!!!!

 

Any suggestions? I was thinkng of returning the card as faulty, but since it works fine in my other pcs (I've tried three now with success) I guess it actually works. Just not in the machine I need to use...

Workstation Intel W2600CR in chassis P4000CR wont show video signal

$
0
0

Hi All,I have bought a new Intel workstation P4000CR which doesnt show anything on screen although the motherboard is active with all status LEDs are green (including the major extrnal one in front and back). the power supply (INTEL redundant power supply 750W) shows a green blinking LED which means it is active and all system fans are active plus CPU fans. it is equipped with two XEON E5-2600 series processors (2640 & 2690) + 4 DIMM's of DDR3 1600MHz RAM memory ECC. none of the DIMM slots error status LED's is on, which indicates no problem with the RAM DIMMS. there are two drives one SATA LG DVD burner + one SATA INTEL SSD. ive tried the onboard matrox 2D GC and an add-on PCI-E 2.0 GC with no success. could anyone pls offer some advice? i'm totaly clueless tried to swith different monitors and it didnt help.

 

Here is the link to the mobo:

ARK | Intel® Workstation Board W2600CR2

JBOD2312S2SP Power Supply Issue?

$
0
0

I have a JBOD2312S2SP Intel Raid Enclosure (Intel® Storage Systems JBOD Family) at my house and woke up to screaming fan noises.  Warning light was blinking and the console showed this:

 

ID = 206

SEQUENCE NUMBER = 164362

TIME = 29-06-2013 03:13:39

LOCALIZED MESSAGE = Controller ID:  0   Power supply cable removed on enclosure:   1      Power Supply   1

 

Note I only have one power supply so if the cable was removed not sure how it was still running.  Right after that warning received the below messages copied from the logs so the top one is the latest:


ID = 243
SEQUENCE NUMBER = 164371
TIME = 29-06-2013 03:13:44
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       3

ID = 243
SEQUENCE NUMBER = 164370
TIME = 29-06-2013 03:13:44
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       2

ID = 243
SEQUENCE NUMBER = 164369
TIME = 29-06-2013 03:13:44
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       1

ID = 243
SEQUENCE NUMBER = 164368
TIME = 29-06-2013 03:13:42
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       3

ID = 243
SEQUENCE NUMBER = 164367
TIME = 29-06-2013 03:13:42
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       2

ID = 243
SEQUENCE NUMBER = 164366
TIME = 29-06-2013 03:13:42
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       1

ID = 243
SEQUENCE NUMBER = 164365
TIME = 29-06-2013 03:13:40
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       3

ID = 243
SEQUENCE NUMBER = 164364
TIME = 29-06-2013 03:13:40
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       2

ID = 243
SEQUENCE NUMBER = 164363
TIME = 29-06-2013 03:13:40
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       1

 

Last message until 6 minutes later I powered up a computer to remove in and shutdown the system.  Pulled the power plug, put it back in, powered everything up, and it's running right now without issue.  Thoughts?

 

Edit:  As a side note, the Intel Raid Web Console shows this drive cage with 2 power supplies.  Always did.  I only have one.  So not sure if that's just how many it can hold or if it's just not intelligent enough to detect the number of drives.

 

Thanks.

 

Steve

IDA: internal error: unable to proceed

Move RAID to new Dell XPS

$
0
0

I have a Dell XPS 8300 with Intel RAID, and have configured two RAID 1 volumes: 1 for System and 1 for Data, each volume using 2 2T drives. Windows 7 is installed and running. I just bought a Dell XPS 8700 -- faster CPU speed, more RAM, and it also includes Intel RAID. I want to move the disks onto the new machine and retain the RAID configuration and the contents. I have a backup, but I think it will be much less work if I can just put the existing configured RAID volumes into the new system without having to re-format the disks and reinstall and restore the backup.

 

Everything I have read suggests that this is not possible -- plugging ANY disk into the machine and setting up RAID will wipe out the disk contents.

 

I can't be the first person in the history of computing who wants to do this kind of upgrade. I expect that, since both systems are Dell and both use the same Intel RAID that there SHOULD be a way to put the disks into service and get the RAID operating without reformatting, rebuilding the RAID and restoring from the backup.

 

Is there a way to do this? Or am I going to have to take the long route and restore from a backup?

 

Anyone at Intel with the intel?

 

Intel Solution FAQ

 

~Joe


RS2BL drivers and RST support?

$
0
0

Hi,

 

I have an RS2BL080 (e or d? spec... the one that supports encryption key management) which has an LSI SAS2108* RAID-on-Chip setup.

 

Are TRIM and\or RST features which these cards already support (and I've just missed it)?

OR will Intel update the drives and software for these cards\chips?

 

----

backstory

 

I purchased a 730 series SSD a few weeks ago after seeing the marketing touting superior RAID-0 speeds, with the plan of getting a second in about month when I can' afford it.... unfortunately I didn't look close enough to realize my card wont support RST and I don't think it even has support for TRIM?

 

I'm just trying to decide what my options are going forward.

Ultimately I'd like to raid 2 (maybe 3 if I can afford it later) 730s with my current RAID card, get the speed, etc. and be done\happy with it!

At this stage if TRIM will be supported, I will probably just swallow the premium cost and grab a second 730 - I would be ok with this.

 

If not, then I have made a mistake getting the 730 because:

A) I need a larger drive

B) Could have chosen a cheaper drive without the premium the 730s have

C) I can't afford a new RAID Controller of the same quality (it was around $900 originally including BBU)

And I'd probably sell and go with something else, which would be a shame.

Intel Server Board S5520SC will not see PCI-e video card

$
0
0

Intel Server Board S5520SC will not see PCI-e video card. It did prior to resetting the BIOS. System will not post with a QuadroFX 5600. Tried another video card and nada, no post. If I put in a really cheap PCI-e video card, it will post.

A few years back told me the BIOS workaround to turn off something? one of the two LAN ports?

I forgot their workaround answer. Any ideas?

Thanks in advance.

Intel Raid SROMBSASMP2 Group Recovery

$
0
0

Hi Guys,

 

I made a mistake and cleared all my configurations on my RAID controller, is it possible to recover the configurations (RAID Groups) and the data that was on them?

 

Cheers,

How to disable PS2/Decay of CPU VR and Memory VR in BIOS, while the CPU and Memory still have P-state and C-state?

$
0
0

How to disable PS2/Decay of CPU VR and Memory VR in BIOS, while the CPU and Memory still have P-state and C-state?

Inconsistent RAID5

$
0
0

Good day.

We have a small RAID5 on an Intel(R) RAID Controller SRCSAS18E comprised of 4 Seagate Cheetah ST3600057SS drives.  The array seems to be functioning fine, however the command:

#  storcli /c0 /v1 show all

results in part:

 

----

 

/c0/v1 :

======

 

---------------------------------------------------------

DG/VD TYPE    State Access Consist   Cache  sCC     Size Name

---------------------------------------------------------

1/1       RAID5   Optl    RW      No         RWTC  -      1.633 TB

---------------------------------------------------------

 

Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|dgrd=Degraded

Optl=Optimal|RO=Read Only|RW=Read Write|B=Blocked|Consist=Consistent|

R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|

AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled

Check Consistency

 

----

From Google I understand that a lack of consistency means problems with parity.  What I have not been able to figure out, and what I am looking for here is what can I do about it?

 

Thanks,

--

David Chapman

dchapman@victoriataxi.com

Viewing all 3923 articles
Browse latest View live