I have a problem. Don´t work. I'm trying connect hardware but the motherboard beats, is it incompatible?
Intel® Server Board S1200SPL and Intel Xeon E3-1245 v5
Intel Embedded Server RAID Technology 2 is not visible under the Advanced tab
I use Intel's dual server S2600CP2 and Windows Server 2008 R2 operating systems. When I set up boot from EFI, Intel Embedded Server RAID Technology 2 could not be found under the Advanced Tab in BIOS, which means I could not use Human Interface Infrastructure Configuration Utility, how should I solve the problem, I checked a lot of Intel's technical documentation, did not find helpful to me.
Intel RAID (RMS3CC080), how to "Online RAID Expansion", cant find it in BIOS or RWC3
Hi
We have a S1200SPOR with RMS3CC080, the below document on page 6 (real PDF page 16) says this controller (and all others that are 12Gb) will:
"Online capacity expansion to add space to an existing drive or a new drive"
"Online RAID level migration"
Ive completed both of the above before with PROMISE controllers and LSI / AVAGO, however i can find anyway in the BIOS or with RWC3 (RAID Web Console 3) to do this, when i select the Virtual Drive there are no options to expand or change the RAID level.
So how is this done?
power 5V for SSD in 1208WTTGSR
S1200SPOR External (PCI-e) display adapter not working
Hi
We have connected a PCI-e display adapter (nVidia) inside this server, Windows 10 does not see any new hardware, we do not get any video from this adapter (on boot or Windows), we have the BIOS drivers loaded.
Are there any standards that need to be met in the new card for the system to see it? How can we tell in BIOS if it sees the new adapter?
The card we are testing (Jaton nVidia VIDEO-PX628GS-LP1), works in other Intel boards (DX79xx series).
Chassis Identity Light
Is it possible to control the chassis identity light from the front panel header in order to make it a appear solid? In effect I would like to be able to use this light to essentially 'beep' out a code as output by our application software. Our host OS is Debian 8, motherboard is an S2600CW2R.
I know that 'ipmi-chassis --chassis-identify=FORCE' (and '=TURN-OFF') can be used to flash the LED indefinetly, but this is at a 1Hz on/off instead of a steady light.
How to set up mail reminder in Intel RSTe?
I use Intel's dual-server server S2600CP2 and Windows Server 2008 R2 operating systems. After installing the INTEL RSTE GUI, when setting up a mail reminder, after entering the SMTP mail server address and port and the sender and recipient email addresses, Send test mail each unsuccessful, for a lot of SMTP mail server address and port number, as well as the sender and the recipient's mail address will not work. And I was thinking, if you do not need to enter the login password of the mailbox, how can it send a test mail? I need to remind the function of mail, how should I properly set it, in order to normal use of the e-mail alert function.
BMC LAN MAC Adress 00:00:00:00:00:00
Hello,
I have configured my BMC LAN for a static configuration using ipmitool. Once I was done I tried pinging it and didn't get a response. I noticed that my mac address was 00:00:00:00:00:00 but everything else looks correct. Has anyone seen this before or figured out how to correct it?
Intel Server Board - S7200AP
BIOS Version - S72C610.86B.01.02.0072.041620172102
#########
# ipmitool lan print 1
Set in Progress : Set Complete
Auth Type Support : MD5 PASSWORD
Auth Type Enable : Callback : MD5 PASSWORD
: User : MD5 PASSWORD
: Operator : MD5 PASSWORD
: Admin : MD5 PASSWORD
: OEM :
IP Address Source : Static Address
IP Address : XX.XX.XX.XX <-- omitted IP address
Subnet Mask : 255.255.255.0
MAC Address : 00:00:00:00:00:00 <--- WHY?
SNMP Community String : public
IP Header : TTL=0x00 Flags=0x00 Precedence=0x00 TOS=0x00
BMC ARP Control : ARP Responses Enabled, Gratuitous ARP Disabled
Gratituous ARP Intrvl : 0.0 seconds
Default Gateway IP : XX.XX.XX.XX <-- omitted GW.
Default Gateway MAC : 00:00:00:00:00:00
Backup Gateway IP : 0.0.0.0
Backup Gateway MAC : 00:00:00:00:00:00
802.1q VLAN ID : Disabled
802.1q VLAN Priority : 0
RMCP+ Cipher Suites : 0,1,2,3,4,6,7,8,9,11,12,13,15,16,17,18
Cipher Suite Priv Max : Xaaaaaaaaaaaaaa
: X=Cipher Suite Unused
: c=CALLBACK
: u=USER
: o=OPERATOR
: a=ADMIN
: O=OEM
############
# ipmitool bmc info
Device ID : 33
Device Revision : 1
Firmware Revision : 1.00
IPMI Version : 2.0
Manufacturer ID : 343
Manufacturer Name : Intel Corporation
Product ID : 117 (0x0075)
Product Name : Unknown (0x75)
Device Available : yes
Provides Device SDRs : no
Additional Device Support :
Sensor Device
SDR Repository Device
SEL Device
FRU Inventory Device
IPMB Event Receiver
IPMB Event Generator
Chassis Device
Aux Firmware Rev Info :
0x01
0x07
0x40
0x28
Thank you so much for your help.
S1200V3RPL Won't Boot
Board was working fine and disconnected from power for about an hour, now is completely dead. The green LED near the P1 power connection on the motherboard lights up but nothing else. No startup sequence or lights on the front, ID and power buttons do nothing.
Have also switched out the PSU in case that was the issue, no difference. No startup, no error codes, no beeps, nothing.
I see there was another thread in the forums with the same issue, but on a new build, with no resolution. Is this board a lemon? We have quite a few servers using this board which makes me very concerned.
Where can I find the SAS drivers?
Hi,
Some basic facts first:
OS: WIndows Server 2016
Motherboard: SuperMicro X9SRi-F
Socket: LGA2011 E5-2600/E5-1600 v2
Chipset: Intel® C602 chipset
I have tried to install the following drivers from Intel's webpage:
Intel® Server Chipset Driver for Windows / Version:10.1.17479.8054
But still I have some missing drivers according to the Device Manager.
It's the built in SAS controller that I seeam to be missing drivers for.
Hardware ID:
PCI\VEN_8086&DEV_1D6B&SUBSYS_062B15D9&REV_06
PCI\VEN_8086&DEV_1D6B&SUBSYS_062B15D9
PCI\VEN_8086&DEV_1D6B&CC_010700
PCI\VEN_8086&DEV_1D6B&CC_0107
And for what I can understand it's Intel's drivers that I need, so where can I find them?
Edit:
Also the Intel® Driver & Support Assistant (Intel® DSA) don't work on Windows Server 2016 why's that?
Query On PCIe in Intel Server System R2224WFTZS
Hi Team,
We have Intel Server System R2224WFTZS with minimum configuration(Single processor & Memory).
Please let me know whether I can use all the available PCIe slots with single CPU?
Thanks!
server health
Atualização S2600cp
bom dia, apos atualizacao da bios, o led ambar fica piscando, diz que e as memorias incorretas mas no IASC todas estao OK.
Intel RAID Web Console 3 - how do we add servers to the GATEWAY server
Hi, downloaded RAID Web Console 3 from here Download Intel® RAID Web Console 3 for Windows*
- Install the GATEWAY server on a remote machine, can log in ok.
- Installed the RAID driver version (SAS v6.713.05.00 (Trimode wont load, even though its listed there doesnt appear to be drivers in the package for this card)) for the RMS3CC090 on a S1200SPOR server running Windows 10 Pro
- Installed the DIRECT AGENT service for RAID Web Console 3 on the above server.
Logging in to the GATEWAY server, then pressing "Re-discover servers", this remote Windows 10 S1200SPOR with the RMS3CC080 never shows up.
We have disabled the firewall on the Windows 10 system
We have disabled the firewall on the gateway server
Is there no way of adding servers to the gateway server?
All documentation for Intel RAID Web Console 3 says the RMS3CC080 is fully supported...
Many Thanks
s2600cp Minimum BIOS to get v2 and DirectX12
Hello
first of all thanks for reading this question , I'd like to say I have little
experience with server boards . But could successfully ensemble my first server , pretty cool .
I've been running my s2600cp , paired with 02 E5-2643 v1 , and 48 GB ram
with no problems , as a Maya/Nuke workstation ( Windows 10 installed )
Now I purchased a GTX 1070 video card but can't run it , probably because the old BIOS
( I got a message error "PCI vendor.." on boot) . Besides I would like to upgrade it to 2x V2 cpus as prices go down,
and I can see on Intel site the minimum BIOS should be 02.01.0002 . Furthermore I bought a USB 3.0
and couldn't get it to work yet .
My current specs :
BIOS............................ SE5C600.86B.01.02.0003
BMC............................. 1.04.2896
SDR package............... 1.03
ME................................ 2.1.5.69
I never tried to update because I read other chat with warnings about trying to update
very old boards could fail and brick it , with some advice to only update BIOS not ME
but the readme.txt say ME must be update as well in order you can go ahead so I got
a bit scared to be honest.
SO my questions are :
0) is it correct , the 02.01.0002 is the minimum bios I need to get v2 CPU compatibility
and directx12 videocards ??? is it correct I need to update all packages ? I dont need server
capabilities only using as workstation ? desktop
1) is it safe to update step-by-step from my current 01.02.0003 to 02.01.0002 ?
2) the update depends upon board releases ? if positive how can I be sure / what should I check ???
3) if its safe please confirm I must go step by step , so I need to download all 6 bios update packages ,
burn it one by one on a USB stick and perform the shell EFI procedure as indicated , it that allright ?
anyone who can give me any advice I welcome and thank in advance !!!!!
regards
Grenchyoll
How to set up mail reminder in Intel RSTe?
I use Intel's dual-server server S2600CP2 and Windows Server 2008 R2 operating systems. After installing the INTEL RSTE GUI, when setting up a mail reminder, after entering the SMTP mail server address and port and the sender and recipient email addresses, Send test mail each unsuccessful, for a lot of SMTP mail server address and port number, as well as the sender and the recipient's mail address will not work. And I was thinking, if you do not need to enter the login password of the mailbox, how can it send a test mail? I need to remind the function of mail, how should I properly set it, in order to normal use of the e-mail alert function.
S2600CP Windows 10 watchdog driver
Good Day.
I am tried enable "OS boot watchdog timer" at BIOS, but my OS (Window 10 - 1709) always rebooted.
I didnt find Intel Watchdog driver and i dont understand how i should install it.
I am really need your help.
How i should check this driver? Does this function support Windows 10?
RMM Status : | Intel(R) RMM not installed |
Device (BMC) Available : | Yes |
BMC FW Build Time : | Mar 23 2017 20:14:24 |
BIOS ID : | SE5C600.86B.02.06.0006.032420170950 |
BMC FW Rev : | 01.28.10603 |
Boot FW Rev : | 01.17 |
SDR Package Version : | �� dd ddd |
Mgmt Engine (ME) FW Rev : | 02.01.07.328 |
power 5V for SSD in 1208WTTGSR
Integrated RAID Module RMS3CC040 - PD is not enterprise class
We have a Server with Integrated RAID Module RMS3CC040 (Firmware Package V: 24.21.0-0012, Firmware Version: 4.680.00-8249) with 3 Samsung 850 Pro Drives RAID 0 (HS)
Every Reboot the Controller shows 3 Warnings: Controller ID: 0 PD is not enterprise class self encrypting drive. Encryption capability of the drive will be disabled -:-:0
We Use AVAGo MSM 17.05.00.02
Any suggestions or ideas ? Thanks in advance.
When can we expect server board firmware updates for the recent vulnerabilities?
Unless I am just not searching your support site properly, I have not been able to find any server firmware updates to address the microcode updates for Meltdown or Spectre or even any notification of a time line. I have a few Intel server that are hosting virtualized environments and would like to see these patched as all of my other server vendors have already delivered these updates.