Quantcast
Channel: Intel Communities : Discussion List - Servers
Viewing all 3923 articles
Browse latest View live

Intel Embedded Server RAID Technology 2 is not visible under the Advanced tab

$
0
0

I use Intel's dual server S2600CP2 and Windows Server 2008 R2 operating systems. When I set up boot from EFI, Intel Embedded Server RAID Technology 2 could not be found under the Advanced Tab in BIOS, which means I could not use Human Interface Infrastructure Configuration Utility, how should I solve the problem, I checked a lot of Intel's technical documentation, did not find helpful to me.


s1200spl fan spin to slow

$
0
0

Hello,

 

my Intel S1200SPL is in a third party case an I got problems with the fan speed. I have two PWM fans and one with 3 pin.

The Fans with PWM spin to slow and the 3 pin fan spin withe 100%. How can I fix this?

I allready made a SDR update and choose "Other Case" and set the fans.

 

Unbenannt.PNG

S1200SPS ESRT2 causes lots of Event ID 153 warnings

$
0
0

Hello,

 

I met a strange issue with this board and ESRT2 driver.

 

For the beginning, I would like to say that, if I do a clean installation of Windows 10 and offer ESRT2 v17 driver and finish installation - all good and no problems.

We have a WDS server for OS installation and if I do a clean installation from there, then there appeard Intel RSTe driver instead, despite the fact I have ESRT2 controller enabled.

The problem appears, when I update this driver to v17 from USB stick and restart the server. Then Event ID 153 with disk warning appears in System Event Log.

Once driver rolled back - all good. I removed all 3d party drivers with DISM and only v17 ESRT2 driver left. Still problem appears.

 

Seems like there is some kind of conflict with another driver or something else. I have 6 servers right now where this problem appears.

Clean installation of Windows 10 solves the problem, but there should be an easier way to fix it.

 

 

Can you give any hint what to try?

 

 

regards,

 

Sergei.

Where to find latest firmware for Server Board s5000XVN/XSL

$
0
0

Hi, I'm trying to find the fix for a really loud fan on this motherboard. All my searches ended up on Workstation board.

 

Is there a way to lower down the fan speeds on idle, since after powering on the machine, for half a minute, minute the fan is really quiet before going full speed again.

 

s5000xvnxsl.JPG

Intel S2600CPJ2 Sensor Reading

$
0
0

Hi All - I have moved the Intel S2600CPJ2 motherboard from Chenbro 1u Server Rack to Phenteck Enthoo Pro case.

 

When i login to the Integrated BMC Web console - i see the following information in the sensor reading. All are green except these below.

 

Can anyone tell me how to fix these and what these means exactly..

                                                                                                                                      

Name                                                              Status                                             Health                         Reading                                                             

         

BB +1.35 P1LV AB                                        All Deasserted                                   unknown                    Not available

BB +1.35 P1LV CD                                        All Deasserted                                   unknown                    Not available

BB +1.35 P2LV AB                                        All Deasserted                                    unknown                    Not available

BB +1.35 P2LV CD                                       All Deasserted                                      unknown                   Not available

Intel RAID (RMS3CC080), how to "Online RAID Expansion", cant find it in BIOS or RWC3

$
0
0

Hi

 

We have a S1200SPOR with RMS3CC080, the below document on page 6 (real PDF page 16) says this controller (and all others that are 12Gb) will:

 

"Online capacity expansion to add space to an existing drive or a new drive"

"Online RAID level migration"

https://www.intel.com/content/dam/support/us/en/documents/server-products/raid-products/12G_RAID_Controllers_UG.pdf

 

Ive completed both of the above before with PROMISE controllers and LSI / AVAGO, however i can find anyway in the BIOS or with RWC3 (RAID Web Console 3) to do this, when i select the Virtual Drive there are no options to expand or change the RAID level.

 

So how is this done?

S1200SPOR External (PCI-e) display adapter not working

$
0
0

Hi

 

We have connected a PCI-e display adapter (nVidia) inside this server, Windows 10 does not see any new hardware, we do not get any video from this adapter (on boot or Windows), we have the BIOS drivers loaded.

 

Are there any standards that need to be met in the new card for the system to see it?  How can we tell in BIOS if it sees the new adapter?

 

The card we are testing (Jaton nVidia VIDEO-PX628GS-LP1), works in other Intel boards (DX79xx series).

s2600cp Minimum BIOS to get v2 and DirectX12

$
0
0

Hello

 

first of all thanks for reading this question  , I'd like to say I have little

experience with server boards . But could successfully ensemble my first server , pretty cool .

I've been running my s2600cp , paired with 02 E5-2643 v1   , and 48 GB ram

with no problems , as a Maya/Nuke workstation ( Windows 10 installed )

 

Now I purchased a GTX 1070 video card but can't run it , probably because the old BIOS

( I got a message error  "PCI vendor.."  on boot) . Besides I would like to upgrade it to 2x V2 cpus as prices go down,

and I can see on Intel site  the minimum BIOS should be 02.01.0002 . Furthermore I bought a USB 3.0

and couldn't get it to work yet .

 

My current specs :

BIOS............................ SE5C600.86B.01.02.0003

BMC............................. 1.04.2896

SDR package............... 1.03

ME................................ 2.1.5.69

 

 

I never tried to update because I read other chat with warnings about trying to update

very old boards could fail and brick it , with some advice to only update BIOS not ME

but the readme.txt say ME must be update as well in order you can go ahead so I got

a bit scared to be honest.

 

SO my questions are :

 

0) is it correct , the 02.01.0002 is the minimum bios I need  to get v2 CPU compatibility

and directx12 videocards ??? is it correct I need to update all packages ? I dont need server

capabilities only using as workstation ? desktop

1) is it safe to update step-by-step from my current 01.02.0003  to 02.01.0002 ?

2) the update depends upon board releases ?  if positive how can I be sure / what should I check ???

3) if its safe please confirm I must go step by step , so I need to download all 6 bios update packages ,

 

 

burn it one by one  on a USB stick and perform the shell EFI procedure as indicated , it that allright ?

anyone who can give me any advice I welcome and thank in advance !!!!!

 

regards

 

Grenchyoll


UEFI Intel RAID (RMS3CC080), stuck on "Driver Health" screen

$
0
0

Hi, i have been playing with the RAID in the hardware (Server is in UEFI mode) (i have not lost data, only test systems).  We cant get in to the BIOS due to the below, so how do we get out of this loop (without removing the RAID hardware card), there must be an answer that works to open the BIOS / RAID utility

 

Please see images:

We had CACHECADE setup (and still connected), now we have the below message:

"There are offline or missing virtual drives with preserved cache.  Please check the cable and ensure that all the drives are present, Press any key to enter the configuration utility."

2018-03-15-raidquestion.jpg

 

 

No matter what we enter (Y, N, C, R, F) the next screen says:

All Driver Health Status List !

2018-03-15-driverhealth.jpg

XXV710DA2OCP 25GbE OCP Modules in S2600WF Wolf Pass Systems

$
0
0

Will the XXV710-DA2 OCP Module (XXV710DA2OCP{1,2}) work in S2600WF Wolf Pass systems, specifically in the R2308WFTZS platform?

 

If so, should one get XXV710DA2OCP1 (OCP Type 1 Mezzanine Module with 8mm stacking) or XV710DA2OCP2 (OCP Type 2 Mezzanine Module with 12mm stacking)?

 

I presume the Type 1 with 8mm stacking since the S2600WFT board already has a cutout in the area designated for the OCP mezzanine module.

Intel RAID Web Console 3 - is there lightweight alternative?

$
0
0

Hi!

I have one RS3DC080 controller on win2016 srv with 8core 1.7GHz CPU.

I have installed Intel RAID Web Console 3 on it and i don't satisfied by that functionality.

Is it possible to automate sending log messages into syslog server or at least into the file using or without webconsole (w/o webconsole case would be preferable)? Now i see just manually log download button in web console.

I have found some log file in C:\Program Files (x86)\LSI\LSIStorageAuthority\logs but there is multiple repeated messages like:

 

13/04 18:56:29 11f0 | Error:  Failed to free Memory

13/04 18:56:59 680 | Error:  Failed to free Memory

13/04 18:57:29 11f0 | Error:  Failed to free Memory

13/04 18:57:54 16e8 | Error:  Failed to free Memory

13/04 18:58:29 11f0 | Error:  Failed to free Memory

13/04 18:58:49 165c | Error:  Failed to free Memory

13/04 18:59:29 11f0 | Error:  Failed to free Memory

13/04 18:59:29 1200 | Warning:  DCMD_FW_call_Info: ctrl=0 DCMD=0x2010000  status=0x0

13/04 18:59:29 1200 | Warning:  DCMD_FW_call_Info: ctrl=0 DCMD=0x2010000  status=0x0

13/04 18:59:29 1200 | Warning:  SL_FW_call_Info: ctrl=0 SL_CMD_TYPE = 6 SL_CMD = 0 status = 0x0

13/04 18:59:29 1200 | Warning:  SL_FW_call_Info: ctrl=0 SL_CMD_TYPE = 6 SL_CMD = 0 status = 0x0

13/04 18:59:29 1200 | Warning:  SL_FW_call_Info: ctrl=0 SL_CMD_TYPE = 6 SL_CMD = 0 status = 0x0

13/04 18:59:29 1200 | Warning:  SL_FW_call_Info: ctrl=0 SL_CMD_TYPE = 6 SL_CMD = 0 status = 0x0

13/04 18:59:29 1200 | Warning:  SL_FW_call_Info: ctrl=0 SL_CMD_TYPE = 6 SL_CMD = 0 status = 0x0

13/04 18:59:29 1200 | Warning:  SL_FW_call_Info: ctrl=0 SL_CMD_TYPE = 6 SL_CMD = 0 status = 0x0

13/04 18:59:29 1200 | Warning:  SL_FW_call_Info: ctrl=0 SL_CMD_TYPE = 6 SL_CMD = 0 status = 0x0

13/04 18:59:29 1200 | Warning:  SL_FW_call_Info: ctrl=0 SL_CMD_TYPE = 6 SL_CMD = 0 status = 0x0

13/04 18:59:29 1200 | Warning:  DCMD_FW_call_Info: ctrl=0 DCMD=0x1010000  status=0x0

13/04 18:59:29 1200 | Warning:  DCMD_FW_call_Info: ctrl=0 DCMD=0x1080101  status=0x0

13/04 18:59:45 6dc | Warning:  DCMD_FW_call_Info: ctrl=0 DCMD=0x5010000  status=0x0

13/04 18:59:45 6dc | Warning:  DCMD_FW_call_Info: ctrl=0 DCMD=0x5030000  status=0x0

13/04 18:59:45 6dc | Warning:  DCMD_FW_call_Info: ctrl=0 DCMD=0x5050100  status=0x0

13/04 18:59:45 6dc | Error:  Failed to free Memory

13/04 19:00:29 11f0 | Error:  Failed to free Memory

13/04 19:00:40 1674 | Error:  Failed to free Memory

13/04 19:01:29 11f0 | Error:  Failed to free Memory

 

while in web console there is nothing erros\warnings:

 

 

Information

 

8

Controller ID: 0 Alarm Enabled by user.

6:48:37 PM,13 Apr'18

 

Information

 

7

Controller ID: 0 Alarm Disabled by user.

6:48:36 PM,13 Apr'18

 

Information

 

44

Controller ID: 0 Time established since power on: Time: 2018-4-13T18:43:35 41 seconds

6:43:35 PM,13 Apr'18

 

Information

 

505

Controller ID: 0 Controller operating temperature within normal range, full operation restored.

35 seconds from Reboot

 

Information

 

547

Controller ID: 0 Inquiry info of PD: Port 4 - 7:1:7 . Inquiry Info - Vendor: HGSTHUH728080AL5204 R5G8N1DV ; Model: HUH728080AL5204 R5G8N1DV ; Serial Number: ; Capacity: 7 TB

34 seconds from Reboot

 

Information

 

247

Controller ID: 0 Device inserted Device Type : Disk Device Id: 15

34 seconds from Reboot

 

Information

 

91

Controller ID: 0 PD inserted : Port 4 - 7:1:7

34 seconds from Reboot

 

Information

 

547

Controller ID: 0 Inquiry info of PD: Port 4 - 7:1:6 . Inquiry Info - Vendor: HGSTHUH728080AL5204 R5G7R9LV ; Model: HUH728080AL5204 R5G7R9LV ; Serial Number: ; Capacity: 7 TB

34 seconds from Reboot

 

Information

 

247

Controller ID: 0 Device inserted Device Type : Disk Device Id: 14

34 seconds from Reboot

 

Information

 

91

Controller ID: 0 PD inserted : Port 4 - 7:1:6

34 seconds from Reboot

 

Information

 

547

Controller ID: 0 Inquiry info of PD: Port 4 - 7:1:5 . Inquiry Info - Vendor: HGSTHUH728080AL5204 R5G7W1BV ; Model: HUH728080AL5204 R5G7W1BV ; Serial Number: ; Capacity: 7 TB

34 seconds from Reboot

 

Information

 

247

Controller ID: 0 Device inserted Device Type : Disk Device Id: 13

34 seconds from Reboot

 

Information

 

91

Controller ID: 0 PD inserted : Port 4 - 7:1:5

34 seconds from Reboot

 

Information

 

547

Controller ID: 0 Inquiry info of PD: Port 4 - 7:1:4 . Inquiry Info - Vendor: HGSTHUH728080AL5204 R5G94X8V ; Model: HUH728080AL5204 R5G94X8V ; Serial Number: ; Capacity: 7 TB

34 seconds from Reboot

 

Information

 

247

Controller ID: 0 Device inserted Device Type : Disk Device Id: 12

34 seconds from Reboot

 

Information

 

91

Controller ID: 0 PD inserted : Port 4 - 7:1:4

34 seconds from Reboot

 

Information

 

547

Controller ID: 0 Inquiry info of PD: Port 0 - 3:1:3 . Inquiry Info - Vendor: HGSTHUH728080AL5204 R5G86D9V ; Model: HUH728080AL5204 R5G86D9V ; Serial Number: ; Capacity: 7 TB

34 seconds from Reboot

 

Information

 

247

Controller ID: 0 Device inserted Device Type : Disk Device Id: 11

34 seconds from Reboot

 

Information

 

91

Controller ID: 0 PD inserted : Port 0 - 3:1:3

34 seconds from Reboot

 

Information

 

547

Controller ID: 0 Inquiry info of PD: Port 0 - 3:1:2 . Inquiry Info - Vendor: HGSTHUH728080AL5204 R5G91HDV ; Model: HUH728080AL5204 R5G91HDV ; Serial Number: ; Capacity: 7 TB

34 seconds from Reboot

 

Information

 

247

Controller ID: 0 Device inserted Device Type : Disk Device Id: 10

R2312WTTYSR won't boot, no video, stopped at POST code "B7h" "Train DDR3 ranks"

$
0
0

I have some R2312WTTYSR systems that, after some downtime prior to OS re-installation, won't come back up again (and so no OS re-installation)

 

Symptoms observed:

 

  • No VGA video output
  • Rear System Status LED gets to a solid Green
  • Amber/Green Diagnostic LEDs stopped at [Amber]1011 [Green]0111, Code B7h for "Train DDR3 ranks"
  • We can access the IPMI/BMC interfaces remotely via their dedicated NICs

 

These are currently using BIOS 01.01.0015 and, I think, ME 03.01.03.021, BMC 01.41.9579, and FRUSDR 112. (yes, an ancient vintage, but it worked).

 

We've left these systems running after boot for about a week just to see if they'd do anything other than sit and "Train DDR3 ranks", but no progress.

 

We've accessed the BMC/IPMI interfaces and have found nothing of note other than reboot events showing up in SEL. We haven't seen anything vaguely resembling a console appear over the RMM4's remote KVM (though, for all I know, Java's messing with me me on the remote KVM part). At least, though, we can reset the systems remotely instead of going deaf standing at the workbench.

 

We've tried forced recovery of the BIOS and even the BMC and ME, but we just can't seem to get this group of systems to make it past "Train DDR3 ranks"

 

Any ideas? Is there some recovery procedure I've missed?  A Technical Advisory?

 

--Jon (who has a similar but hopefully unrelated problem with an S1200SP system to ask about)

R1208SPOSHOR won't boot, no video, stopped at POST code 78h "DXE ACPI Init"

$
0
0

I have one R1208SPOSHOR system that, after a BIOS/FW/etc update to the latest version and a reset to defaults, won't come back up again.

 

Symptoms observed:

 

  • No VGA video output
  • Rear System Status LED gets to a solid Green
  • Amber/Green Diagnostic LEDs stopped at [Amber]0111 [Green]1000, Code 78h for "DXE ACPI Init"
  • We can't access the IPMI/BMC interfaces remotely via their dedicated NICs (it comes up via DHCP, but we can't login)

 

This was recently updated, along with 9 other R1208SPOSHOR systems of identical config, to BIOS 03.01.0028, ME 04.01.04.054, BMC 01.12.11072, and FRUSDR V0.26.

 

We've left this system running after boot for about a week just to see if it would do anything other than sit at "DXE ACPI Init", but no progress.

 

We've tried forced recovery of the BIOS and even the BMC and ME, but we just can't seem to get this system to show us anything on console to even give us a hint as to why it gets stuck in POST where it does.

 

Any ideas? Is there some recovery procedure I've missed?  A Technical Advisory?

 

In the meanwhile, I'll try to regain login access to the IPMI/BMC interfaces.

 

--Jon

S5000PSL (S5000SL) / Fan´s running at 100% / Status LED Amber / Sys-Fan LED Amber

$
0
0

Hello,

 

I have the current problem:

 

I have an INTEL S5000PSL installed with 16GB RAM (4x4) and two Xeon 51xx. The MoBo is installed in an Intel Chassis SC5400 (I don´t know the exactly model and don´t know how to identify)

 

The Problem is that all Fans running at 100% all the time after the newest BIOS UPDATE (Download Firmware Update Package for DOS ). The settings in Bios were loaded to optimzied settings (F9) and the Fanspeed to Acoustic, 0-300.

I had also resetted the CMOS and the BMC jumper but no solution....

 

I had recognized that the SYSTEM_STATUS_LED is currently blinking orange/amber all the time also when WIN SERVER 2012 R2 is running.

The SYS_FAN_LED (left back near by RAM) is also lightning in amber but I have installed an 4-PIN PWM Fan....

 

I don´t know what I can do else. Do you have any information how I can get the fan´s silent/running in Idle mode?

 

Thanks in advance

Samsung 960 EVO NVMe M.2 SSD PCI-e and S2600CW2

$
0
0

Hi there,

 

I'm trying to setup a Samsung m.2 with the S2600CW2 motherboard in a dual xeon configuration but it seems it can't be detected by the system.

 

Any ideas to make it work??

 

Many thanks,


Intel RAID Web Console 3 - how do we add servers to the GATEWAY server

$
0
0

Hi, downloaded RAID Web Console 3 from here Download Intel® RAID Web Console 3 for Windows*

 

- Install the GATEWAY server on a remote machine, can log in ok.

- Installed the RAID driver version (SAS v6.713.05.00 (Trimode wont load, even though its listed there doesnt appear to be drivers in the package for this card)) for the RMS3CC090 on a S1200SPOR server running Windows 10 Pro

- Installed the DIRECT AGENT service for RAID Web Console 3 on the above server.

 

Logging in to the GATEWAY server, then pressing "Re-discover servers", this remote Windows 10 S1200SPOR with the RMS3CC080 never shows up.

We have disabled the firewall on the Windows 10 system

We have disabled the firewall on the gateway server

 

Is there no way of adding servers to the gateway server?

 

All documentation for Intel RAID Web Console 3 says the RMS3CC080 is fully supported...

 

Many Thanks

BMC LAN MAC Adress 00:00:00:00:00:00

$
0
0

Hello,

 

I have configured my BMC LAN for a static configuration using ipmitool.  Once I was done I tried pinging it and didn't get a response.  I noticed that my mac address was 00:00:00:00:00:00 but everything else looks correct.  Has anyone seen this before or figured out how to correct it?

 

Intel Server Board - S7200AP

BIOS Version - S72C610.86B.01.02.0072.041620172102

 

#########

# ipmitool lan print 1

Set in Progress         : Set Complete

Auth Type Support       : MD5 PASSWORD

Auth Type Enable        : Callback : MD5 PASSWORD

                        : User     : MD5 PASSWORD

                        : Operator : MD5 PASSWORD

                        : Admin    : MD5 PASSWORD

                        : OEM      :

IP Address Source       : Static Address

IP Address              : XX.XX.XX.XX <-- omitted IP address

Subnet Mask             : 255.255.255.0

MAC Address             : 00:00:00:00:00:00 <--- WHY?

SNMP Community String   : public

IP Header               : TTL=0x00 Flags=0x00 Precedence=0x00 TOS=0x00

BMC ARP Control         : ARP Responses Enabled, Gratuitous ARP Disabled

Gratituous ARP Intrvl   : 0.0 seconds

Default Gateway IP      : XX.XX.XX.XX <-- omitted GW.

Default Gateway MAC     : 00:00:00:00:00:00

Backup Gateway IP       : 0.0.0.0

Backup Gateway MAC      : 00:00:00:00:00:00

802.1q VLAN ID          : Disabled

802.1q VLAN Priority    : 0

RMCP+ Cipher Suites     : 0,1,2,3,4,6,7,8,9,11,12,13,15,16,17,18

Cipher Suite Priv Max   : Xaaaaaaaaaaaaaa

                        :     X=Cipher Suite Unused

                        :     c=CALLBACK

                        :     u=USER

                        :     o=OPERATOR

                        :     a=ADMIN

                        :     O=OEM

 

############

# ipmitool bmc info

Device ID                 : 33

Device Revision           : 1

Firmware Revision         : 1.00

IPMI Version              : 2.0

Manufacturer ID           : 343

Manufacturer Name         : Intel Corporation

Product ID                : 117 (0x0075)

Product Name              : Unknown (0x75)

Device Available          : yes

Provides Device SDRs      : no

Additional Device Support :

    Sensor Device

    SDR Repository Device

    SEL Device

    FRU Inventory Device

    IPMB Event Receiver

    IPMB Event Generator

    Chassis Device

Aux Firmware Rev Info     :

    0x01

    0x07

    0x40

    0x28

 

Thank you so much for your help.

HFI1 opainfo state in INIT

$
0
0

I try to install Intel Omni path in rhel 7.4 below, error i got

 

[root@skl18cn001 ~]# opainfo

hfi1_0:1                           PortGUID:0x00117501017be229

   PortState:     Init (LinkUp)

   LinkSpeed      Act: 25Gb         En: 25Gb

   LinkWidth      Act: 4            En: 4

   LinkWidthDnGrd ActTx: 4  Rx: 4   En: 1,2,3,4

   LCRC           Act: 14-bit       En: 14-bit,16-bit,48-bit       Mgmt: True

   Xmit Data:                  0 MB Pkts:                 2414

   Recv Data:                  1 MB Pkts:                 8294

   Link Quality: 5 (Excellent)

 

 

[   11.448156] hfi1 0000:3b:00.0: hfi1_0: Setting partition keys

[   11.448170] hfi1 0000:3b:00.0: hfi1_0: set_link_state: current VERIFY_CAP, new GOING_UP

[   11.448196] hfi1 0000:3b:00.0: hfi1_0: hfi1_ibphys_portstate: physical state changed to PHYS_TRAINING (0x4), phy 0x46

[   11.448210] Couldn't create new SM AH

[   11.986950] ip6_tables: (C) 2000-2006 Netfilter Core Team

[   11.996107] Ebtables v2.0 registered

[   12.113233] bridge: filtering via arp/ip/ip6tables is no longer available by default. Update your scripts to load br_netfilter if you need this.

[   12.116756] tun: Universal TUN/TAP device driver, 1.6

[   12.116757] tun: (C) 1999-2004 Max Krasnyansky <maxk@qualcomm.com>

[   12.117337] virbr0: port 1(virbr0-nic) entered blocking state

[   12.117340] virbr0: port 1(virbr0-nic) entered disabled state

[   12.117505] device virbr0-nic entered promiscuous mode

[   12.151186] nf_conntrack version 0.5.0 (65536 buckets, 262144 max)

[   12.183571] virbr0: port 1(virbr0-nic) entered blocking state

[   12.183573] virbr0: port 1(virbr0-nic) entered listening state

[   12.183691] IPv6: ADDRCONF(NETDEV_UP): virbr0: link is not ready

[   12.196546] virbr0: port 1(virbr0-nic) entered disabled state

[   13.654791] hfi1 0000:3b:00.0: hfi1_0: 8051: Link up

[   13.654814] hfi1 0000:3b:00.0: hfi1_0: set_link_state: current GOING_UP, new INIT (LINKUP)

[   13.654817] hfi1 0000:3b:00.0: hfi1_0: logical state changed to PORT_INIT (0x2)

[   13.654823] hfi1 0000:3b:00.0: hfi1_0: Fabric active lanes (width): tx 0xf (4), rx 0xf (4)

[  107.774441] loop: module loaded

[  107.788846] ISO 9660 Extensions: Microsoft Joliet Level 3

[  107.791273] ISO 9660 Extensions: RRIP_1991A

[  294.183366] hfi1 0000:3b:00.0: hfi1_0: hfi1_ibphys_portstate: physical state changed to PHYS_LINKUP (0x5), phy 0x50

[ 7727.776139] nr_pdflush_threads exported in /proc is scheduled for removal

 

 

Please help to solve this issue. Here i am attached opacapture tar file.

s1200spl fan spin to slow

$
0
0

Hello,

 

my Intel S1200SPL is in a third party case an I got problems with the fan speed. I have two PWM fans and one with 3 pin.

The Fans with PWM spin to slow and the 3 pin fan spin withe 100%. How can I fix this?

I allready made a SDR update and choose "Other Case" and set the fans.

 

Unbenannt.PNG

Can IPMI check the option item in BIOS?

$
0
0

I want to check whether the Boot option in the BIOS is UEFI or Legacy BIOS.

Can it be done through IPMI?

What is the command?

Viewing all 3923 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>