ESXi 5.1 could not see storage of Intel Server R2304LH2HKC.

$
0
0

Dear Intel Support.

 

I just got Inter Server R2304LH2HKC few days ago.  Please see invoice in the attachment file. (bill.jpg)

 

I can use VMware ESX 5.1 and 5.5. in this server by install VMware on the USB. Both ESX version

can boot properly.  But it could not see the storage of the server.  Even I try to use both of raid version

Intel ESRT2 (LSI)’ and ‘Intel RSTe’.

 

Please see Raid screen below.

 

- Raid configuration on Bios.

001.jpg

 

- Raid of the ‘Intel RSTe’.

002.jpg

 

- Raid of the ‘Intel ESRT2 (LSI)’.

003.jpg

 

Usually when I buy server from Dell or IBM.  If this problems occur.  They will let me download the

software installation of ESX version (ISO file) which support the storage.

 

If you don’t have solution like the IBM or Dell.  Could you let me know how to solve this problems ???

How do I add the storage raid driver in ESX ???  I don’t know name of the chipset of this RAID because
it’s raid onboard.

 

Please accept my extreme thanks in advanced for your kindness.

 

*** I already call Intel support at telephone number 0018006310003.  Mr.Sumatha he said that this is software it can not support ESX 5.1.  Ohhhhh this is hardware raid surely because it press (ctrl+i) or (ctrl+e), this is characteristic of hardware raid.  Moreover it’s only hardware raid support HotSwap.  The software raid must install OS first then install the driver.  I don’t know why he say like that.  He make me upset too much.

 

*** Please look at specification of your Intel server in the attachment file 's4600lh.pdf' on page number 4.  It’s hardware raid because it support HotSwap.

004.jpg

 

I believe in Intel.  Please don't leave me alone.  Thank you.


I get bad support from Intel about Intel Server 'R2304LH2HKC'. How I do ???

$
0
0

I believe in Intel but your staff could not support your product 'Intel Server 'R2304LH2HKC' which expensive than $12,000.  How customer know ???

001.jpg

 

002.jpg

 

003.jpg

 

004.jpg

 

005.jpg

S2600WT2 BMC fails to renew dhcp address

$
0
0

Hi there,

 

we have a number of S2600WT2 servers and on occasion some (few) of them fail to renew their IP address via DHCP, e.g. after having restarted the dhcp server for maintenance. This is particularly annoying if the node was powered off since I can't reach it in-band, either, and thus lost all ability to control it.


The only failsafe method to recover known to us is to break the physical network link momentarily, which apparently causes the bmc dhcp client to renew its address. Is this a bug in the bmc dhcp client? Has anyone experienced this situation before?


Thanks & cheerio, Harry.





S1200v3rp Raid 1 setup with two partitioned 2TB Hard Drives

$
0
0

We typically use a simple RAID 1 configuration with 2 hard driives, and a System/Data partition, with the obvious goal of being able to continue operating if one drive fails.  Our latest system shows two RAID Arrays:  Partition 1 (System) was created (Array 00), and then the RAID configured, and then Partition 2 (Data/Shares) was created and this became Array 1. Disk Management shows a Disk 0 (500GB) and a Disk 1 (1.5TB), so Windows Server thinks that the partitioned drive is actually two separate disks.  If this is a good way to configure the system I'd like to know; remember our only goal is to have redundancy in the event of a single hard drive failure.  If not I'd like to know about it before it goes into production.  Thx in advance!

S1200V3RPS ESRT2 Raid10 multiple hard disk failure.

$
0
0

 

A have three different S1200V3RPS servers configured with ESRT2 Raid10 (sata).
N
ow and then out of the blue too or three disks fail at the same time resulting in corrupt data.

You don’t get any warning’s, it just happens.

W
e have the latest bios firmware and ESRT2 drivers.
W
e have several servers with the older S1200BTL with the same raid setup and the work just fine.

 

Intel Raid SRCZCR - Need to get data off this old server. Array currently in ERROR state.

$
0
0

Hello...

 

I know this server is old, but i need to get the data off it. 

Not sure how to recover or best method or steps in StorCon.

Guide says contact intel, but not supported.

Its a Raid 5 Array, and i believe i had 4 drives with a hotfix, but i have 3 drives that are currently in ready state, and 2 missing.

How can i get the rebuild process started by replacing one bad drive ?

 

Appreciate (Begging )  any insight to attempt to rebuild this array!

 

Thanks

Mike

SR2600URBPR with ASR26XXFHLPR five slot active riser do not recognize five PCIe v2.0 x2 cards based on Marvel 9230 chipset

$
0
0

Server stops diagnostics with 0x51code on diag leds - Allocating resources to PCI buses..

I take out the two cards - no problem..

I tried to put in two PCIe x4 intel network server cards instead controllers - the same situation - 0x51 code..

SR2520 server system power supply problem

$
0
0

Hi,

 

I have an SR2520 with two hot-swap power supply modules. One of them is blinking green, the other one is solid amber. The power/sleep led on the front control panel is solid green. The server does not boot. Where can I find any information about this power supplies (the meaning of the led lights) or any idea what could be the problem?

 

Sorry, the power/sleep led has no light at all, the System Status LED is the solid green (that means normal operation but still no activity from the server). The rest of the LEDs are off too.

 

Message was edited by: Gabor Kohlrusz


S2600CW mother board and Broadwell chips

$
0
0

Broadwell chips were installed in a S2600CW motherboard but the board would not come out of DXE IPL, post Diagnostic = 0x4f.

 

The BIOS chip on the S2600CW was then replaced with the BIOS chip provided in the Software Development Platform box.  Now the motherboard repeatedly turns the CPU fans on at a low RPM for a couple of seconds and then the board rolls over.

 

What should I do at this point?

Совместимые ОС для сервера S3210SH

$
0
0

Доброго времени суток. Хочу установить Windows 7x64 на сервер модель S3210SH. Это возможно? Загрузочный диск с Windows 7, сервер не видит, а при установке Windows Server 2003 R2

RAID wird 3tb Hdds on WX58BP

$
0
0

Hi,

Im planning to build a little homeserver/nas with a WX58BP Board running 4x3tb in an raid5. The problem is that the BIOS recognizes the 3tb drives as 801gb drives, but in Windows i can see the whole capacity.

I googled a lot and found out that the ich10 v 10.1 cant handle drives with 3tb, but the latest BIOS update v042 for my Mainboard includes only v10.1 of the storage controller. Is there any possibility to get a newer Version of the ich10 into my BIOS?

 

Best regards Joshua

Help

$
0
0

Good day!!

I wonder what processor is compatible with the mother board (server board S3200SH)

I am using an asterix and the current processor not realizing this.

I wonder what processor I could buy to improve my performance.

Thank you

Server response slow

$
0
0

Info: The server configuration is as follows

Test server 1:

Server chassis: CHENBRO CHASIS Model: RM-41416B

Motherboard: Intel Server board S2600CP4

Processor: Intel XEON E5-2630 V2 (Single CPU)

RAM: 8GB RAM Samsung ECC RDIMM (2 no’s)

RAID controller: LSI MegaRAID 9271-4i SGL SATA+SAS Part No: LSI00328

RAID level: RAID1 and RAID0

RAID card to HDD connector: Mini SAS to 4 SATA CABLE SAS PCI D33289-003 BIZLINK (Intel)

HDD type: SATA (Seagate Constellation ES.3)

Network: 1 Gbps (2 no’s with route add enabled)

Antivirus and firewall: Symantec Endpoint Protection 12.4 (Firewall disabled)

RAID configuration details: Totally 7 HDDs are connected to the server (All are 1TB SATA HDDs). We have configured 3 RAID1 pairs using 6 HDDS (Each RAID1 is equal to 1TB) and 1 HDD as RAID0.

First RAID1 has 4 partitions. One is for OS and other 3 are used for just keeping very less accessed/ less important waste files).

Other 2 RAID1 HDDs have 4 partitions in each and all are shared over LAN. RAID0 HDD has 8 partitions with low level data and it is also shared over LAN.

Test server 2:

IBM System X3630 M4 Rack Server

Processor:Intel Xeon E5-2420 (6 core, 15MB)

RAM: 8GB

HDD: 4x 1TB (RAID 1)

RAID controller card: M5110 RAID

Problem Description:

Initially the test server 2 was my main server and everything was fine, I changed my main server with test server 1 now the problem started like I faced the problem like the clients experienced the interaction with the server is slow and unable to work fast. So I reverted back the changes in order to do the testing and I made the test server 1 as client but now also I faced some issues with working speed of the server. So I decided to do some loop testing which is...

Test suite1:

For i = 0 To TextBox1.Text

For j = 0 To TextBox2.Text

        If j = TextBox2.Text Then

               Me.Text = j

            End If

      Next

Next

Result:

Loops   Test server 1   Test server 2

         (in sec)      (in sec)

 

10000   304.0282       301.2274

10000   259.9276       285.3041

10000   234.016        282.9914

20000   985.8125       1247.3977

20000   944.6284       1142.5796

20000   1033.9074      1245.3892

 

Test suite 2:

  1. VB.net

For i = 0 To TextBox1.Text

    If i <> TextBox1.Text Then

         Me.Text = i

    End If

    For j = 0 To TextBox2.Text

    Next

Next

Result:

  1. VB.net

Loops   Test server 1   Test server 2

         (in sec)        (in sec)

10000     0.9984         0.6566

10000     0.9984         0.6564

10000     0.9984         0.6406

20000     1.8096         1.4219

20000     2.106           1.4377

20000     2.1216         1.4844

 

Changes done:

  1. 1. I checked the same with the multiple OS like windows 2008 and 2012 but still the same problem repeated
  2. 2. Checked without RAID
  3. 3. Done complete hardware check with the intel
  4. 4. I also tried by removing the RAID and other extra HDDs. I just ran the server with single HDD (That is OS HDD) and still the problem remained same

The test server 2 was lesser capacity server as per hardware configuration. Still the speed of the test server 1 seems slow when it runs the programme.

Is there anything I left to check and is there any other way to solve this problem?? Please help me...


Thank you in advance..

Can SS4200E software be run on a SS4200ENH?

$
0
0

Can the software which was packaged with the SS4200E be installed on the SS4200ENH and therefore be run like a SS4200E NAS?

 

Namely:

 

Storage System Software 1.1.11.32736 Firmware

Storage System Manager for Windows - English 1.1.11.32736 Utilities, Tools and Examples

Open-Source and GPL components 1.1 Source Code

 

 

From what little I have been able to read it seems that the hardware is exactly the same. Are they?

 

Thank You

Don Resor

Los Angeles

Help me choose memory modules

$
0
0

I have a motherboard S3420GPLX and processor Xeon X3450.

http://ark.intel.com/ru/products/46545/Intel-Server-Board-S3420GPLX

http://ark.intel.com/ru/products/42929/Intel-Xeon-Processor-X3450-8M-Cache-2_66-GHz

 

I want to install 32 GB of memory.

 

Now we can buy such modules:

 

Kingston ValueRAM KVR13R9S4L/8  DDR-III DIMM 8Gb  PC3-10600  ECC Registered with Parity CL9

Kingston ValueRAM KVR16LR11S4/8  DDR-III DIMM 8Gb  PC3-12800  ECC Registered with Parity CL11

Kingston ValueRAM KVR16LR11S4L/8  DDR-III DIMM 8Gb  PC3-12800  ECC Registered with Parity, Low Profile CL11

Kingston ValueRAM KVR16R11S4/8  DDR-III DIMM 8Gb  PC3-12800  ECC Registered with Parity CL11

Kingston ValueRAM KVR16R11S4/8I  DDR-III DIMM 8Gb  PC3-12800  ECC Registered with Parity CL11

Kingston ValueRAM KVR18R13S4/8  DDR-III DIMM 8Gb  PC3-15000  ECC Registered with Parity CL13

Kingston ValueRAM KVR16E11/8  DDR-III DIMM 8Gb  PC3-12800  CL11 ECC

Kingston ValueRAM KVR16LR11D8/8  DDR-III DIMM 8Gb  PC3-12800  ECC Registered with Parity, Low Voltage CL11

Kingston ValueRAM KVR1333D3E9S/8G  DDR-III DIMM 8Gb  PC3-10600  ECC CL9

Kingston ValueRAM KVR13LE9/8  DDR-III DIMM 8Gb  PC3-10600  CL9 ECC

Kingston ValueRAM KVR13LR9D8/8  DDR-III DIMM 8Gb  PC3-10600  ECC Registered with Parity, Low Voltage CL9

Kingston ValueRAM KVR13R9D8/8  DDR-III DIMM 8Gb  PC3-10600  ECC Registered with Parity CL9

Kingston ValueRAM KVR16E11/8I  DDR-III DIMM 8Gb  PC3-12800  ECC CL11

Kingston ValueRAM KVR16LE11/8  DDR-III DIMM 8Gb  PC3-12800  CL11 ECC, Low Voltage

Kingston ValueRAM KVR16R11D8/8  DDR-III DIMM 8Gb  PC3-12800  ECC Registered with Parity CL11

Kingston ValueRAM KVR18E13/8  DDR-III DIMM 8Gb  PC3-15000  ECC CL13

Kingston ValueRAM KVR18R13D8/8  DDR-III DIMM 8Gb  PC3-15000  ECC Registered with Parity CL13

 

 

Which memory modules are compatible with this motherboard?


S2600CW2 motherboard sata0-3 ports

$
0
0

Hi,

 

I have recently purchased an Intel S2600CW2 server board. Sorry in advance if this question is obvious, but, for the life of me I can not figure out what kind of cable I need to connect to the SATA 0-3 ports. They are not standard sata ports, and as far as I can tell they are not mini-sas either, I purchased a mini-sas cable and it did not fit.

 

Can someone direct me to the cable which can fit into this connector?

 

Thanks

Robert

Change from Raid 0 to Raid 1

$
0
0

My server was in Raid 1 and I messed up and got it changed to Raid 0, and I need to get it back to Raid 1.  Is there any way to do that with out doing a restore from backup?  If not, what would be the steps to get it back to Raid 1.  It is currently on 2 drives and I would be willing to start with 2 new drives just to make sure it works.  Thank you for any help.

server SR2500

$
0
0

Hi , We have problem server Intel SR2500 the server hang , and there is no post , no video output

NAS Intel SS4200E power supply is burned

$
0
0

I have a NAS Intel SS4200E

The power supply is burned how can I purchase a new one?

extra connector from p4304xxshcn front panel goes where on s1200v3rp board

$
0
0

Extra connector from p4304xxshcn front panel goes where on s1200v3rp board.

It's 2x2 pins in a 3x2 sized connector. The s1200v3rp board has 2 1x2 headers (J1F1 Chassis Intrusion Header and J1G2 HDD LED Header)

next to the larger front panel header J1C3.

Viewing all 3923 articles