Quantcast
Channel: Intel Communities : Discussion List - Servers
Viewing all 3923 articles
Browse latest View live

SS4000-E 100% Full Can't access data, enable FTP, or SSH

$
0
0

I've been using this Grrrrreat NAS Array and had been working for YEARS. Just last week it is now 100% Full and my share is gone.

 

It has FW fs-bc 1.3-b524,   4 x 500GB HD's   and a 1.3TB shares (but i cant access any of the shares \\share any more), but I can PING the NAS

 

Here is a lot info so you can get idea on the status on the array;

 

 

I can login into browser (using Firfox ver 29) the 3 x Green lights are on, the 4 HD's show (and are powered on and green {even during a bootup they do light up in order top/bottom}) also show Hot plug Indicator (in yellow) they are all  ST3500641AS (465GB each), I can't expand the share (it shows i have only available disk space is -2 MB free), It will not let me enable FTP (the on/off button shows, but will not complete when i enable it), i can't enable SSH (the on button shows, but will not complete when i press it), The SHARED folders show NOT READY backup clients NOT Ready. Under the SYSTEM Status screen  CPU is 100% Idle (all day long, even after a reboot(s)), network IPs are still good, FANs are 1704 RPM, disk temps are 54,35,38 Deg C, i can't even make a XRAY and save the file. I've tried using many ver of IE, Google chrome.


So, now I'm asking this community if you can help me. I've ran out of ideas on what to do. I also have the org Recovery CD's (but the PC i'm using does not support the NIC). Is there ANY WAY I can access the DATA off these HD's from ANY other way? like BOOT a CD using USB, Or access the data and maybe del a folder or 2 to free up some space, so that it will boot up.  or some other Advance HTTP CGI script (fsck check, del temp files..etc), that will enable me to see the boot up, or enable TFTP (i even tried to connect using that) or any other copy job.


i have been reading the posts and i did find out someway  you can make a serial ribbon cable and show the boot up (by taking case off), but i have not tried that part yet.


Any help you can give?


Thank you for your time.


P4308RPLSHDR mounting RAID cache battery

$
0
0

Hello,

 

The P4308RPLSHDR has an 8 bay hot swap HDD unit that blocks the RAID cacher battery mounting location.

 

Where do Intel suggest the cache battery be mounted in this chassis as a result of the designed position being unavailable

 

Regards,

 

GT

S4600LH, flashupdt, system freeze

$
0
0

I have a new S4600LH with an old BIOS that doesn't recognize my E5-4627 V2 CPU's.  I am running Centos 6.5. with the latest updates as of today.

 

I downloaded the flashupdt utility and installed the RPM, but when I run it the system immediately locks up and requires the reset button -- the watchdog process reboots it after a short while.

 

I tried with both the -i and -u options and it locked up the same way.  The -h option works at least.  Here is where the lock up happens:

 

# /usr/bin/flashupdt/flashupdt -i

 

  One Boot Flash Update Utility Version 11.0 Build 15

  Copyright (c) 2013 Intel Corporation

 

(zzzzzzz, system is frozen at this point)

 

What do I have to do to make flashupdt work?  I'll try the UEFI process just for fun, but the Linux utility is the most important one to get working.  Don't you have a way for the BIOS to read the updates from a CDROM (or USB-copied CDROM image)?  That would be much more compatible and easy to use than any of these other methods.

 

Thanks,

Mark

SR2612UR server reboots with CATERR

$
0
0

Hello,

 

I have a SR2612UR server with S5520UR board and RS2bl040 raid controller. I have recentrly installed some Samsung SSD's and the performance was improved but after a few days the server rebooted unexpectedly. In Intel Active System Console i found the following logs:

 

2014-05-12 15:19:08BIOS Evt Sensor reports Timestamp Clock Sync. Event is first of two expected events from BIOS on every power on.InformationalOpen10.1.1.234177
2014-05-12 15:20:02OS Boot sensor 0 reports the boot from drive C has been completed.InformationalOpen10.1.1.234178
2014-05-12 15:20:02Operating system bootup.InformationalOpen10.1.1.234179
2014-05-12 15:19:46BIOS Evt Sensor reports a system boot event has occurred.InformationalOpen10.1.1.234180
2014-05-12 15:18:45CATERR reports it has been asserted.CRITICALClosed10.1.1.234181
2014-05-12 15:18:50Pwr Unit Status reports the power unit is powered off or being powered down.InformationalClosed10.1.1.234182
2014-05-12 15:18:42BIOS Evt Sensor reports Timestamp Clock Sync. Event is second of two expected events from BIOS on every power on.InformationalClosed10.1.1.234183
2014-05-12 15:18:55Pwr Unit Status reports the power unit is powered on.InformationalClosed10.1.1.234184
2014-05-12 15:18:56CATERR reports it has been deasserted.InformationalClosed10.1.1.234185

 

I found on some other forums that C6 State setting from BIOS could cause some troubles and disabling could solve those random reboots. Coult that be the sollution? Is there any side effects for disabling C6 CPU State?

S1600JP Just pulled it out of the box, and tried to upgrade the BIOS and now it doesn't post?

$
0
0

I pulled this server out of the box and installed 8gb of ram and a E52603 V2 Chip in it.

 

It came up and posted.

 

It warned me that I needed to install the latest bios to make this Processor work correctly. < this is lame that the server isn't ready for a processor out of the box.

 

So I thought this shouldn't be to hard,

 

Intel® Server Board S1600JP Family and Intel Server System R1000JP IDA

Firmware Update Package for Intel® Deployment Assistant, Intel® One Boot Flash Update Utility, The embedded EFI Shell, Windows* Preboot

I loaded this on a USB drive thinking it would be the right one to update. The Words "One Boot Flash Update Utility." Really grabbed my eyes as being the right one. So if its wrong I am sorry.

 

So I booted up and the usb drive was found, and it said it would upgrade unless I hit esc. So I let it run.

 

When I thought it was done, it said it had completed and gave me 5 options and the 5th one was to exit. I choose 5, and it did a few things and told me I should restart the system using the from panel. I assumed that it meant the power button. So I pressed it.

 

That was the end.

 

Now when I press the power button it just acts like it's turning on but it doesn't post anything on the screen.

 

Yes I checked the cable it's on it snug.

 

Any thoughts????

MFSYS25 - One Drive in Storage Array Failing Causes Entire Chassis to Fail?

$
0
0

Hello,

 

We have an MFSYS25 chassis (details below) which has a strange but rather critical problem.

 

Whenever a drive fails on the RAID setup we have the entire system locks up. The fans speed up; all of the compute modules restart but do not go anywhere, and we can barely manage the system as the management console hangs up. What we find that we have to do is completely unplug and plug back in the power to the system and then start the rebuild on the failed drive. Then, we can start the compute modules and get the various servers going again, etc.

 

Has anyone else experienced this? What can we do to add some resiliency to the system?

 

Thank you for your time.

 

Details of our MFSYS25 System are as follows:

 

  1. Chassis Management Module: Part Number: D70735-403
  2. Server Storage Module: Part Number: D70737-404
  3. Gigabit Ethernet Switch: Part Number: D70739-404
  4. Six (6) Server Compute Modules: Part Number: D70726-404
  5. Firmware Versions:
    1. Server 1BMC Firmwareok1.36.6
      BMC Bootok0.10
      BIOSokSB5000.86B.10.00.0050.083120090939
      Server 2BMC Firmwareok1.36.6
      BMC Bootok0.10
      BIOSokSB5000.86B.10.00.0050.083120090939
      Server 3BMC Firmwareok1.36.6
      BMC Bootok0.10
      BIOSokSB5000.86B.10.00.0050.083120090939
      Server 4BMC Firmwareok1.36.6
      BMC Bootok0.10
      BIOSokSB5000.86B.10.00.0050.083120090939
      Server 5BMC Firmwareok1.36.6
      BMC Bootok0.10
      BIOSokSB5000.86B.10.00.0050.083120090939
      Server 6BMC Firmwareok1.36.6
      BMC Bootok0.10
      BIOSokSB5000.86B.10.00.0050.083120090939
      Switch 1Firmwareok1.0.0.27
      Bootok1.0.0.6
      Switch 2Firmwarenot present--
      Bootnot present--
      Storage Control Module 1Firmwareok3.10.140.2
      Storage Control Module 2Firmwarenot present--
      System Fan 1Firmwareok1.2
      Bootok1.2
      System Fan 2Firmwareok1.2
      Bootok1.2
      I/O FanFirmwareok1.2
      Bootok1.2
      Power Supply 1Firmwarenot applicable --
      Bootnot applicable --
      Power Supply 2Firmwarenot applicable --
      Bootnot applicable --
      Power Supply 3Firmwarenot applicable --
      Bootnot applicable --
      Power Supply Blank 4Firmwareok1.2
      Bootok1.2

MFSYS25 And Promise Vtrack e310s

$
0
0

Hello,

 

I have an Intel Multiflex system MFSYS25 with six blades and an Promise vTrak e310s.

4 of the servers have internal storage presented but i want that the other two servers to boot from Promise and use a shared lun. I followed the instructions in the connection guide from intel but when i'm trying to boot the second server, the first one freezes and cannot access the storage.

What is strange, is that even i don;t have any internal storage presented to the servers, in the LSI sas from the blade i see a lun 0 Multiflex V-LUN. How can i disable it?

I have to mention that i use RedHat Enterprise Linux 6.5 on the servers.

 

Please advice,

 

Thank you,

George Pochiscan

What is best practice for Intel RST RAID chipset and Linux?

$
0
0

I have servers and desktops with Intel RST RAID chipset on the board.  I want to install Centos Linux 5 or 6.

I read many posts on the Internet and understand that RST is host-based or "fake" RAID.  I also downloaded the Intel RST pdf on this subject, but the document doesn't give pros and cons on setting up in the BIOS other than the boot loader is stored there.


So what is the best practice for setting up RAID-1 (mirror) on Linux boxes.


Should I setup as mirror in the BIOS?  Centos 5.9 and later have the drivers and will view the RAID as a single volume during install.

Should I leave the disks as independent non-RAID and setup as software RAID?

I will install the mdraid or dmraid afterwards to check status, etc.


What is the best practice for this and what are disadvantages of setting up as mirror in the BIOS?


Thank you.


Fan Speed Issue

$
0
0

I bought a new Intel R2208GZ4GC with 2 E5 2680V2 CPU.

 

As a result of a high workload, the CPUs are getting very hot with about 75°C, but the fans are still very low with about 2.418 rpm.

 

My actual bios configuration:

 

Set Fan Profile: performance

Fan PWM Offset: 100

Altitude: 300-900m

Set Throttling Mode: auto

 

OS: Ubuntu 14.04 LTS

 

What should I have to do to tell the fans to increase the speed?

 

Thanks,

 

Bikearni

No usable memory found - Server board

$
0
0

Hi,

 

I trying to assemble my workstation at home.

The motherboard is S2600cP2,

The CPUs are E-2620 V2 (dual)

Memory Modules are kvr13lr9d4/16ha

 

When i try to powerup the machine it boots up with the following message with 3 beeps

Installed BIOS: SE5C600.86B.01.08.0003

Platfrom ID: s2600CP

No usable memory found.

 

Is this issue related to the

lower BIOS version/ Due to the CPUs which might require a bios upgrade.

or

Incompatible DDR3 memory.

 

Thanks,

Vishnu

Problem with Intel RAID Controller RS3UC080

$
0
0

I have an RSCUC080 RAID Controller card and the arrays connected to this controller randomly disappear from the system.  The arrays usually reappear after rebooting the machine, but every once in a while they do not and I have to reboot multiple times.  This usually happens at least once a day and has been going on for several weeks.  I did not have this problem the first several week I had this card.  The controller card is still under warranty, but I wanted to see if anyone has any suggestions about what the problem could be before submitting a warranty claim.

 

I have the latest BIOS and firmware for all the components below including the RS3UC080.

 

Thanks,

Shane

 

SYSTEM

Case: NORCO RPC-4220 4U Rackmount Server Chassis w/ 20 Hot-Swappable SATA/SAS 6G Drive Bays (currently using 11 drive bays)

Motherboard: ASRock Z87 Extreme6

CPU: Intel Core i5-4670K Haswell

Memory: 16 GB Crucial Ballistix Sport (PC3 10600)

Graphics: MSI R7 265 2GD5 OC 2GB 256-Bit GDDR5

RAID Controller 1: Onboard

     SSD: SAMSUNG 840 EVO MZ-7TE250BW 2.5" 250GB

     Array: RAID 10 using four 3GB SATA 6 hard drives (it is using a mixture of desktop and NAS drives and there are no issues with this array)

RAID Controller 2: RSCUC080 (both of the following arrays randomly disappear)

     Array 1: RAID 0 using three 1 TB hard drives (these are all 3 Gbps, desktop drives)

     Array 2: RAID 10 using four 3 TB SATA 6 hard drives (all HGST Deskstar NAS 3TB 7200 RPM 6 Gbps)

2 - PCI TV Tuner Cards

1 - PCI Express TV Tuner Card

Power Supply: EVGA Supernova 1300 G2 (1300W Gold Power Supply)

3 - SilenX EFX-12-15 120mm Effizio Quiet Case Fan                                                                                                                                                                                                  

2 - SilenX EFX-08-15 80mm Effizio Quiet Case Fan                                                                                                                                                                                                   

Windows 8.1 Update 1 with Media Center

S2600CP CPU Fan Control

$
0
0

I just built a new server with a S2600CP motherboard, Xeon E5 CPU and BXSTS100C Cooler. It's all up and running quite well, but the CPU fan is LOUD!. It's obviously running at full speed, as you can hear it step up during the boot process. The cooling fins are almost cold due to the high air flow,  is there some way to lower the fans speed and ths reduce the noise coming from this thing?

 

Thanks in advance.

Intel SS4000-E keeps shutting down

$
0
0

Dear all,

 

my SS4000-E NAS keeps on shutting down and i have no possibility to access or copy my data. hope you can help me out.

System boots up and after 5 min it automatically shuts down. I've changed the network and power cable, both cooling fans are working fine, no firmware update done recently, etc.

 

Any ideas to solve the issue?

 

System:

- RADI 1, 2x 1GB Drives

- Firmware:   fs-bc - 1.4-b710

- System Log:

 

Date/TimeTypeEvent

 

May 23 09:19:03ISystem starting up
May 23 09:12:33INetwork connection restored (Port 1) (1000 Mbps Full Duplex )
May 23 09:12:14IDynamic network address now [eth0:192.168.10.14/255.255.255.0 ]
May 23 09:00:52INetwork connection restored (Port 1) (1000 Mbps Full Duplex )
May 23 09:00:33IDynamic network address now [eth0:192.168.10.14/255.255.255.0 ]

 

- Both cooling fans are working fine

- No Harddisk error, Harddisk status Yellow.

 

Other possibilities:

How could i copy the data from one harddisk to another PC/NAS? Do i need an extra controller?

 

many thanks in advance,

best

g

Difference between Megacli(Storcli) and Intel command tool 2 utility

$
0
0

Hi,

 

I'm currently investigating megacli and Cmdtool2 and I want to know what is the difference between the two ? Are they identical and Cmdtool2 is just a wrapper around megacli or their implementation is different ? Also, does anyone know what is the performance of both the utility ?

 

Thanks

Vaibhav

QPI link rate test failed by Intel Processor Diagnostic Tool with Haswell-EP 2.40Ghz ES L0 stepping CPU

$
0
0

Hello,

 

I had tried to diagnose Intel Grentley platform with two Haswell-EP 2.40Ghz ES L0 stepping 12 core 135W CPU installed by Intel Processor Diagnostic Tool v2.10.0.0.MP under Windows Server 2008 R2 SP1 x64 OS but got QPI link rate test failed message here, also the FSB could not be detected, I've no idea if IPDT support Haswell-EP CPU or not, but the BIOS could detect QPI link rate as 9.6T/s correctly, please advise.

 

Below is the test result of IPDT:

 

---------------------------
--- Testing Processor 1 ---
---------------------------


--- IPDT64 - rev  2.10.0.0.MP ---


--- Start Time: 05/27/2014 00:29:14---


--- Skipping Config ---


--- Reading CPU Manufacturer ---

Expected --> GenuineIntel
Detected --> GenuineIntel
Found --- Genuine Intel Processor ---

--- Temperature Test ---

Temperature Test Passed!!!


Temperature = 59 degrees C below maximum.


--- Reading Brand String ---

Detected Brand String:
Genuine Intel   2.40GHz

Brand String Test Passed!!!


--- Reading CPU Frequency ---

Expected CPU Frequency is --> 2.40


Detected CPU Frequency is --> 2.40026

CPU Frequency Test Passed!!!


--- FSB NOT Supported on this Processor ---


--- Running Base Clock test ---


Detected Base Clock --> 100
Base Clock test Pass ---
--- Error while retrieving QPI Link rate  ---
..QPI Link rate Test Failed..

QPI Link rate Test Failed. Error while retrieving QPI Link rate

--- Error while retrieving QPI Link rate  ---
..QPI Link rate Test Failed..

QPI Link rate Test Failed. Error while retrieving QPI Link rate


--- Test End Time: 05/27/2014 00:29:16---


---------------------------
--- Testing Processor 2 ---
---------------------------


--- IPDT64 - rev  2.10.0.0.MP ---


--- Start Time: 05/27/2014 00:29:16---


--- Skipping Config ---


--- Reading CPU Manufacturer ---

Expected --> GenuineIntel
Detected --> GenuineIntel
Found --- Genuine Intel Processor ---

--- Temperature Test ---

Temperature Test Passed!!!


Temperature = 62 degrees C below maximum.


--- Reading Brand String ---

Detected Brand String:
Genuine Intel   2.40GHz

Brand String Test Passed!!!


--- Reading CPU Frequency ---

Expected CPU Frequency is --> 2.40


Detected CPU Frequency is --> 2.82848

CPU Frequency Test Passed with Warning!!!

The processor frequency could be affected by power management features. In order
to ensure the processor frequency is not affected by a power management setting,
enter BIOS, load defaults, and disable any 'Over-Clocking' or power
management features that may affect processor frequency. Also, set any
software applications which control power management features to default.


--- FSB NOT Supported on this Processor ---


--- Running Base Clock test ---


Detected Base Clock --> 101
Base Clock test Pass ---
--- Error while retrieving QPI Link rate  ---
..QPI Link rate Test Failed..

QPI Link rate Test Failed. Error while retrieving QPI Link rate

--- Error while retrieving QPI Link rate  ---
..QPI Link rate Test Failed..

QPI Link rate Test Failed. Error while retrieving QPI Link rate


--- Test End Time: 05/27/2014 00:29:17---


-----------------------------------
--- Multi Processor Stress Test ---
-----------------------------------


--- IPDT64 - rev  2.10.0.0.MP ---


--- Start Time: 05/27/2014 00:29:17---


--- Skipping Config ---


--- Multi Proc Load ---


--- Multi Processor Load Level set to - 64 - for - 4 - minutes ---


..Multi Proc Stress Load Passed..


--- Test End Time: 05/27/2014 00:33:19---

 


    ---------------
    --- Summary ---
    ---------------

Processor Status
    1  Fail
    2  Fail

System Information
------------------
Processor Name: Genuine Intel(R) CPU @ 2.40GHz
Processor Information: Intel64 Family 6 Model 63 Stepping 1
Number of Physical Cores: 24
Number of Logical Cores: 24
Installed System Memory: 192 GB
Operating System: Microsoft Windows Server 2008 R2 Enterprise 64-bit
Graphics Information: Matrox G200e (ServerEngines)
System Product: ŸŸŸŸŸŸŸŸŸŸŸŸŸŸŸŸ
System BIOS: 00.80

 

And below is the CPU information captured from CPU-Z v1.69.0.x64:

 

Processor 1ID = 0
     Number of cores12 (max 16)
     Number of threads12 (max 32)
     NameIntel Core i3/i5/i7 4xxx
     CodenameHaswell
     SpecificationGenuine Intel(R) CPU @ 2.40GHz (Engineering Sample)
     Package (platform ID)(0x0)
     CPUID6.F.1
     Extended CPUID6.3F
     Core Stepping
     TDP Limit135 Watts
     Tjmax103.0 蚓
     Core Speed1199.7 MHz
     Multiplier x Bus Speed12.0 x 100.0 MHz
     Stock frequency2400 MHz
     Instructions setsMMX, SSE, SSE2, SSE3, SSSE3, SSE4.1, SSE4.2, EM64T, VT-x, AES, AVX, AVX2, FMA3
     L1 Data cache12 x 32 KBytes, 8-way set associative, 64-byte line size
     L1 Instruction cache12 x 32 KBytes, 8-way set associative, 64-byte line size
     L2 cache12 x 256 KBytes, 8-way set associative, 64-byte line size
     L3 cache30 MBytes, 20-way set associative, 64-byte line size
     FID/VID Controlyes
     Turbo Modesupported, enabled
     Max non-turbo ratio24x
     Max turbo ratio27x
     Max efficiency ratio12x
     Max Power270 Watts
     Min Power58 Watts
     O/C binsnone
     Ratio 1 core30x
     Ratio 2 cores29x
     Ratio 3 cores28x
     Ratio 4 cores27x
     Ratio 5 cores27x
     Ratio 6 cores27x
     Ratio 7 cores27x
     Ratio 8 cores27x
     Ratio 9 cores27x
     Ratio 10 cores27x
     Ratio 11 cores27x
     Ratio 12 cores27x
     Ratio 13 cores27x
     Ratio 14 cores27x
     Ratio 15 cores27x
     Ratio 16 cores27x
     Ratio 17 cores27x
     Ratio 18 cores27x
     TSC2400.0 MHz
     APERF1200.0 MHz
     MPERF2400.0 MHz
     IA Voltage ModePCU adaptive
     IA Voltage Offset0 mV
     GT Voltage ModePCU adaptive
     GT Voltage Offset0 mV
     LLC/Ring Voltage ModePCU adaptive
     LLC/Ring Voltage Offset0 mV
     Agent Voltage ModePCU adaptive
     Agent Voltage Offset0 mV
Processor 2ID = 1
     Number of cores12 (max 16)
     Number of threads12 (max 32)
     NameIntel Core i3/i5/i7 4xxx
     CodenameHaswell
     SpecificationGenuine Intel(R) CPU @ 2.40GHz (Engineering Sample)
     Package (platform ID)(0x0)
     CPUID6.F.1
     Extended CPUID6.3F
     Core Stepping
     TDP Limit135 Watts
     Tjmax103.0 蚓
     Core Speed1199.7 MHz
     Multiplier x Bus Speed12.0 x 100.0 MHz
     Stock frequency2400 MHz
     Instructions setsMMX, SSE, SSE2, SSE3, SSSE3, SSE4.1, SSE4.2, EM64T, VT-x, AES, AVX, AVX2, FMA3
     L1 Data cache12 x 32 KBytes, 8-way set associative, 64-byte line size
     L1 Instruction cache12 x 32 KBytes, 8-way set associative, 64-byte line size
     L2 cache12 x 256 KBytes, 8-way set associative, 64-byte line size
     L3 cache30 MBytes, 20-way set associative, 64-byte line size
     FID/VID Controlyes
     Turbo Modesupported, enabled
     Max non-turbo ratio24x
     Max turbo ratio27x
     Max efficiency ratio12x
     Max Power270 Watts
     Min Power58 Watts
     O/C binsnone
     Ratio 1 core30x
     Ratio 2 cores29x
     Ratio 3 cores28x
     Ratio 4 cores27x
     Ratio 5 cores27x
     Ratio 6 cores27x
     Ratio 7 cores27x
     Ratio 8 cores27x
     Ratio 9 cores27x
     Ratio 10 cores27x
     Ratio 11 cores27x
     Ratio 12 cores27x
     Ratio 13 cores27x
     Ratio 14 cores27x
     Ratio 15 cores27x
     Ratio 16 cores27x
     Ratio 17 cores27x
     Ratio 18 cores27x
     TSC2399.9 MHz
     APERF1199.9 MHz
     MPERF2399.9 MHz
     IA Voltage ModePCU adaptive
     IA Voltage Offset0 mV
     GT Voltage ModePCU adaptive
     GT Voltage Offset0 mV
     LLC/Ring Voltage ModePCU adaptive
     LLC/Ring Voltage Offset0 mV
     Agent Voltage ModePCU adaptive
     Agent Voltage Offset0 mV

 

Thanks,

Jacky

 

訊息由此人編輯:Jacky Lee


Intel Embedded Raid Controller WD4000F9YZ

$
0
0

Hi,

 

i have an older Intel Server with S5000VSA, latest Firmware and Updates installed. Windows 2012 Server Standard as OS. I added 2 WD4000F9YZ 4TB drives to the internal RAID controller, but when I go into the Configuration Utility at Startup using Ctrl+E the two drives are shown with the correct type, but only 1717783MB of capacity, which is about half of the real size. On another Computer the drive is recogniced correct with 4TB.

Using the Raid Web Console (newest Version) they aren't shown at all. Under physical are only my two old WD 600GB SATA drives???

 

Please help

Fritz Hajek

Server takes 40 seconds for completing POST

$
0
0

My server takes a long time to get past the POST. Below is my configuration,

It takes about 40 seconds to just complete the POST and show any kind of display on the monitor.

I have updated the firmware to the latest found on intel's website but still no luck. I have tried disabling network boot, disabling/enabling Quiet boot....nothing works.

Please help me with getting this fixed.

 

=======================================

Processor:         Intel Xeon 1245 v3

Motherboard:      Intel Server Board DBS1200v3RPS

RAM:                Crucial 1866 Mhz (8 GB ECC Unbuffered) single module

PSU:                Corsair 650W

CPU Cooler:      Antec A40

HDD:                Seagate 1 TB (7200 RPM)

=====================================

Intel Server Board S2600GZ (Server System R1208GL4DS) & Memory

$
0
0

Hello!

 

I've just buy Server Intel R1208GL4DS with two Xeon E5-2620v2 and installed 8 x Crucial 8192Mb DDR3 1600MHz ECC Reg modules (CT8G3ERSLD4160B).

It wont start in spite of all green leds tell me that all is OK.

I've read instruction and found that S2600GZ Server Board is not support 1600MHz low voltage (1.35v) modules.

After it I've tried to install ordinary DDR3 DIMMs (no ECC, no Reg). Result is the same.

 

The question is: server wont start because these types of DIMMs are not supported? Or possible it is something wrong Server Board or CPU?

I'm asking because it will take a very lot of time for me to change DIMMs or/and Board to another.

 

Signs are:

- three green leds are lighting (System Status LED, 12 Volt Stand-By Present LED, System Power Good LED),

- no any leds are lighting, 

- "No signal" monitor screen,

- fans are rotating,

- keyboard "Num lock" not changing.

 

Any help are highly appreciated!

 

With best wishes,

Maxim

Intel S1200BTSR Vt-d?

$
0
0

Hi


I have a question about the Intel S1200BSTR Serverboard. I would like to build a ESX Lab and Need a Server Board with vt-d Support (for TV Card passtrough). I see in the specifications that this board will Support vt-d. In some communitys i had read that the board will not Support vt-d. I wrote a Email to Intel Support and they told me that it will Support vt-d. Whats is correct now?


Does anyone has practical experience with that board and can tell me if it will work or not?

I will use the following Processor with support vt-d: Intel E3 1265Lv 2

Regards
Rico


S5520UR BMC lost

$
0
0

Hi Experts,

 

I have an S5520UR motherboard in a SR2612UR server.

It worked for years but before a new OS install I decided to update it to the latest (already 3 years old) firmware.

I installed the BIOS60/BMC58/FUR26/ME112 via the the EFI shell.

During the update I already noticed that the FRU and ME updates are failed saying "BMC are already in firmware transfer mode".

After reboot I noticed that I BMC LAN menu is greyed out in BIOS.

 

I removed the power cord redo the update with same result, Boot block are showing version 0.00

I tried the force update jumper according to: https://communities.intel.com/message/86309#86309

reset to default bios settings, force update on and back again but it does not fixed the BMC.

 

Luckily the machine boots, works ok, but I`m afraid without a working BMC it will not run well and maybe damaged.

Do you have any advice what should I try to resurrect the BMC ?

What is you opinion about running the server without working BMC ?

 

I wish you have a better luck.

Viewing all 3923 articles