The server cannot push the pin code, and the debug test indicates the error message.
“No servers listed. Trying DNS service record:_uniteservice._tcp”
The server cannot push the pin code, and the debug test indicates the error message.
“No servers listed. Trying DNS service record:_uniteservice._tcp”
hi there i hope someone knows whats going on here
i have the S2600CP motherboard where it works perfectly fine with 2x 2609 cpu´s but will not work with 2x 2660v2 cpu´s
i have updated the motherboard bios to the latest version BIOS - 02.06.0006 i still always get this error
but it will work if i just use one of them i have also check what the led post code means and that came up short
it lights up led numbers 7 6 5 and 3 2 1
i am starting to tear my hair trying to figure out what the problem
the ram im using is 8 gigs on 4 sticks at 1333mhz non ecc and the ram works just fine with the 2609 cpu´s
if i am missing anything i would very much like to hear about it or if you have a magic solution for this
Hi,
I've been trying to get a KNL on the HNS7200AP compute module to post, but it seems to be stuck at post code 0x19: SB PEIM, and occasionally resets itself and ges stuck again. Are there any suggestions on how to debug this issue?
All help is appreciated.
Thanks,
Brian
Добрый день !
У меня подобная проблема которая тут обсуждалась. Ответа на вопрос я не нашёл и поэтому повторяю :
Remote Management Module key : Installed
Device (BMC) Available : Yes
BMC FW Build Time : 2018-06-07 11:48:53
BIOS ID : SE5C610.86B.01.01.0027.071020182329
BMC FW Rev : 1.53.11210
Boot FW Rev : 1.07
SDR Package Version : SDR Package 1.17
Mgmt Engine (ME) FW Rev : 03.01.03.050
Baseboard Serial Number : BQTP61800321
Сенсоры в BMC WEB console :
VRD Hot All deasserted OK 0x0000
DIMM Thrm Mrgn 1 Normal OK -48 degrees C
DIMM Thrm Mrgn 2 Normal Unknown Not Available
DIMM Thrm Mrgn 3 Normal OK -51 degrees C
DIMM Thrm Mrgn 4 Normal Unknown Not Available
Agg Therm Mgn 1 Normal OK -7 degrees C
Постоянно, приблизительно каждые 5 минут в сфере vmware выходит сообщение о температуре на DIMM. Помогите от этого избавиться.
for english :
Good afternoon !
At me a similar problem which here was discussed.I did not find the answer to the question and therefore I repeat:
Remote Management Module key: Installed
Device (BMC) Available: Yes
BMC FW Build Time: 2018-06-07 11:48:53
BIOS ID: SE5C610.86B.01.01.0027.071020182329
BMC FW Rev: 1.53.11210
Boot FW Rev: 1.07
SDR Package Version: SDR Package 1.17
Mgmt Engine (ME) FW Rev: 03.01.03.050
Baseboard Serial Number: BQTP61800321
Sensors:
VRD Hot All deasserted OK 0x0000
DIMM Thrm Mrgn 1 Normal OK -48 degrees C
DIMM Thrm Mrgn 2 Normal Unknown Not Available
DIMM Thrm Mrgn 3 Normal OK -51 degrees C
DIMM Thrm Mrgn 4 Normal Unknown Not Available
Agg Therm Mgn 1 Normal OK -7 degrees C
Constantly, approximately every 5 minutes in the vmware sphere there is a message about the temperature on the DIMM.
help please get rid of it.
Is it possible to control the chassis identity light from the front panel header in order to make it a appear solid? In effect I would like to be able to use this light to essentially 'beep' out a code as output by our application software. Our host OS is Debian 8, motherboard is an S2600CW2R.
I know that 'ipmi-chassis --chassis-identify=FORCE' (and '=TURN-OFF') can be used to flash the LED indefinetly, but this is at a 1Hz on/off instead of a steady light.
Hi,
is possible to install on an S2600CP that has 8 RAM modules 16 Gb. Kingston KVR16R11D4/16 (1600MHz, ECC, CL11, 1.5V) other 8 modules KVR16LR11D4/16 (1600MHz, ECC, CL11, 1.35V)?
Is the mix of RAM of the same type but with different voltage supported?
Thanks for the reply
Dear support,
We have one server S2600WT and this RS3DC040 RAID controller with battery.
All worked fine over a year, but at some day it started to give an overheating error.
But temperatures are Ok and it is 16C degrees in server room.
We upgraded all firmwares, that were possible to upgrade - that helped for few days.
Then we changed a RAID controller to a brand new one - didn't help.
When we unplugged battery - didn't help
We unplugged battery controller from RAID card - that helped and server stopped beepeing.
We changed this battery module to a new one - didn't help.
There is no errors in RAID console, but just beeping.
How can we solve this issue?
regards,
Sergei.
The TPS for the S2600WF server board and the R2000WF series servers offer, in Appendix B (pages 120 and 125, respectively), a diagnostic LED decoder., as shown below.
I have a customer who reports POST fails, with a "32" on the video display, and
Amber : ON ONONoff Green: ON ONONoff seen on the rear diagnostic LEDs.
The POST progress code example tables (same pages) indicates that's a error hex code EE (or binary 1110 1110).
However, in the pages which follow, there is no error code EE(or binary 1110 1110)described in either TPS.
I have a new server with the Intel S1200SPS server mainboard. I installed Server 2016 on a RAID 1 virtual disk, which was setup in the RAID BIOS (ESRT II) with dual Samsung EVO 250GB SSD's. The RAID was also configured with an additional RAID 1 virtual drive of 2 2-TB WD Gold drives for data storage.
It was working fine until I shipped it out to my client. The mainboard was damaged in shipping, (would not power up to POST) so I replaced it with the same exact model, I checked all other components using hardware diagnostics, including Samsung SSD diagnostics and WD Lifeguard to be sure nothing else was damaged (being sure not to affect data on the drives). The diagnostics was performed on a separate system, and I could read the drives individually, that the OS and files are there.
After re-assembling the system, I reconfigured the BIOS to use RAID for SATA, and because it's a new mainboard, re-setup the RAID 1 virtual drives, and setting the SSD RAID pair as bootable in the ESRT II BIOS. I did a consistency check on both RAID virtual drives, which went well, fixing inconsistencies. I then set the BIOS to boot from the RAID Array. At this point, I figured it would boot up as originally. However, windows doesn't recognize the RAID drives, and so won't boot up. When I got into recovery mode command prompt, the virtual drives are not available at all (not listed in the wmic logicaldisk list).
I'm hoping you Intel guys have done this type of thing before and have a trick up your sleeve to help me get Server 2016 to boot again and not have to lose the hours of time spent installing and configuring Server and other software. Any ideas?
The server cannot push the pin code, and the debug test indicates the error message.
“No servers listed. Trying DNS service record:_uniteservice._tcp”
Just a quick question about server support. Is there support around the world for Intel servers such as HP or IBM will have? Like fast response time and easy replacement. I assume yes because it is Intel, but I do not know for sure.
Hi Intel Support,
We're assemblying 3 servers, 1st and 2nd server has no problem on the assembly and now we're having issues on my third assembly of Intel Server System, to give you details of the Server system, please see below.
3 out of 16 RAM are having issue not usual issue or behaviours.
1st and 2nd RAM with issue installed on DIMM_A1 and DIMM_B1 slot was appearing "Installed&Failed", the RAM is causing the memory module next to them to fail which is installed DIMM_A2 and DIMM_B2.
We tried to replace the RAM installed to DIMM_A1 and DIMM_B1 it with good RAM and no problem encountered.
Other issue to third RAM, We have installed RAM to DIMM_C1, DIMM_C2, DIMM_D1, DIMM_D2.
When the 3rd RAM with issue was installed to DIMM_C1 is was appearing "Not Installed" and all other RAM installed to DIMM_C2, DIMM_D1, DIMM_D2 will appearing "Not Intstalled" too.
We tried to replace the 3rd RAM installed to DIMM_C1 and all the RAM installed to DIMM_C2, DIMM_D1, DIMM_D2 will all be "Installed&Operational.
Have your team, encountered this king of issue with Kingston? Please advice us and I need your opinion what is causing this king of issues?
Thanks in advance.
Johnson
Before I had the same problem with motherboard which reported Platform ID as S2600SDP
Intel has replaced motherboard to me by standard warranty as wrong motherboard
New board has correct identification. And Power Supply FAN was working quietly.
Support person recommended me to upgrade BIOS on new received board and the story has repeated.
Power Supply fan rotates at max speed.
It is not PS Fan fault. It is some other fault.
As I know already, the loud PS Fan is made for signalling of critical system faults.Customer support by phone replies too slow.
So I decided to ask here.
Please, help me identify the fault source. ( taking into account that fault raised right after BIOS UPGRADE )
I attach sysinfo logfiles here
Thank you.
Hi, i have been playing with the RAID in the hardware (Server is in UEFI mode) (i have not lost data, only test systems). We cant get in to the BIOS due to the below, so how do we get out of this loop (without removing the RAID hardware card), there must be an answer that works to open the BIOS / RAID utility
Please see images:
We had CACHECADE setup (and still connected), now we have the below message:
"There are offline or missing virtual drives with preserved cache. Please check the cable and ensure that all the drives are present, Press any key to enter the configuration utility."
No matter what we enter (Y, N, C, R, F) the next screen says:
All Driver Health Status List !
Hi
We have a S1200SPOR with RMS3CC080, the below document on page 6 (real PDF page 16) says this controller (and all others that are 12Gb) will:
"Online capacity expansion to add space to an existing drive or a new drive"
"Online RAID level migration"
Ive completed both of the above before with PROMISE controllers and LSI / AVAGO, however i can find anyway in the BIOS or with RWC3 (RAID Web Console 3) to do this, when i select the Virtual Drive there are no options to expand or change the RAID level.
So how is this done?
Hi, downloaded RAID Web Console 3 from here Download Intel® RAID Web Console 3 for Windows*
- Install the GATEWAY server on a remote machine, can log in ok.
- Installed the RAID driver version (SAS v6.713.05.00 (Trimode wont load, even though its listed there doesnt appear to be drivers in the package for this card)) for the RMS3CC090 on a S1200SPOR server running Windows 10 Pro
- Installed the DIRECT AGENT service for RAID Web Console 3 on the above server.
Logging in to the GATEWAY server, then pressing "Re-discover servers", this remote Windows 10 S1200SPOR with the RMS3CC080 never shows up.
We have disabled the firewall on the Windows 10 system
We have disabled the firewall on the gateway server
Is there no way of adding servers to the gateway server?
All documentation for Intel RAID Web Console 3 says the RMS3CC080 is fully supported...
Many Thanks
Добрый день !
У меня подобная проблема которая тут обсуждалась. Ответа на вопрос я не нашёл и поэтому повторяю :
Remote Management Module key : Installed
Device (BMC) Available : Yes
BMC FW Build Time : 2018-06-07 11:48:53
BIOS ID : SE5C610.86B.01.01.0027.071020182329
BMC FW Rev : 1.53.11210
Boot FW Rev : 1.07
SDR Package Version : SDR Package 1.17
Mgmt Engine (ME) FW Rev : 03.01.03.050
Baseboard Serial Number : BQTP61800321
Сенсоры в BMC WEB console :
VRD Hot All deasserted OK 0x0000
DIMM Thrm Mrgn 1 Normal OK -48 degrees C
DIMM Thrm Mrgn 2 Normal Unknown Not Available
DIMM Thrm Mrgn 3 Normal OK -51 degrees C
DIMM Thrm Mrgn 4 Normal Unknown Not Available
Agg Therm Mgn 1 Normal OK -7 degrees C
Постоянно, приблизительно каждые 5 минут в сфере vmware выходит сообщение о температуре на DIMM. Помогите от этого избавиться.
for english :
Good afternoon !
At me a similar problem which here was discussed.I did not find the answer to the question and therefore I repeat:
Remote Management Module key: Installed
Device (BMC) Available: Yes
BMC FW Build Time: 2018-06-07 11:48:53
BIOS ID: SE5C610.86B.01.01.0027.071020182329
BMC FW Rev: 1.53.11210
Boot FW Rev: 1.07
SDR Package Version: SDR Package 1.17
Mgmt Engine (ME) FW Rev: 03.01.03.050
Baseboard Serial Number: BQTP61800321
Sensors:
VRD Hot All deasserted OK 0x0000
DIMM Thrm Mrgn 1 Normal OK -48 degrees C
DIMM Thrm Mrgn 2 Normal Unknown Not Available
DIMM Thrm Mrgn 3 Normal OK -51 degrees C
DIMM Thrm Mrgn 4 Normal Unknown Not Available
Agg Therm Mgn 1 Normal OK -7 degrees C
Constantly, approximately every 5 minutes in the vmware sphere there is a message about the temperature on the DIMM.
help please get rid of it.
I have made a server setup with 2 xeon e5 2620-v4 processor.
my pc starts but stuck at boot. USB ports are not working as keyboard and mouse are not working. screen stuck at
"Warning: This server is running factory firmware.
A software update is required.
Please load the latest system update package(SUP)
to unable the latest security, quality and performance capabilities.
Hello!
On new R2208WFTZS server upgraded firmware package from stock 00.01.0009 to 00.01.0014 and now fans are on 7000RPM all the time.
All fan are working and I do not see any errors. See attached Sysinfo logs.
Does any one of you have idea how to solve this issue?
Regards,
Kuba W.