I can not configure a software RAID of 5 disks on the R1208WTTGSR platform. Need raid 10 + 1 hot spare. In the BIOS, sata (0-3 port) and ssata (0-3 port) are available. It turns out that 2 different baskets! Accordingly, a raid can be created from only 4 disks! How to combine them into one basket? To make a raid you can create from 5, 6, 7 disks !!!
RAID of 5 disks on the R1208WTTGSR
s1200spl fan spin to slow
Intel RAID Web Console 3 - how do we add servers to the GATEWAY server
Hi, downloaded RAID Web Console 3 from here Download Intel® RAID Web Console 3 for Windows*
- Install the GATEWAY server on a remote machine, can log in ok.
- Installed the RAID driver version (SAS v6.713.05.00 (Trimode wont load, even though its listed there doesnt appear to be drivers in the package for this card)) for the RMS3CC090 on a S1200SPOR server running Windows 10 Pro
- Installed the DIRECT AGENT service for RAID Web Console 3 on the above server.
Logging in to the GATEWAY server, then pressing "Re-discover servers", this remote Windows 10 S1200SPOR with the RMS3CC080 never shows up.
We have disabled the firewall on the Windows 10 system
We have disabled the firewall on the gateway server
Is there no way of adding servers to the gateway server?
All documentation for Intel RAID Web Console 3 says the RMS3CC080 is fully supported...
Many Thanks
S2600WT2R Motherboard onboard nic
The onboard nic cards just quit working. Vendor wants to replace entire server because of the contract agreement we have with them. (a whole other story). How does one go about getting warranty service on a motherboard when you can't even get your vendor to help you out?
BMC server health amber
Hi,
In the BMC panel we have server health status blinking in amber state (failure) but all sensors state to OK.
What can be an issue for this ?
Br,
S1200SPLR - SAS Module Compatibilty Questions
Hi,
I'm using a S1200SPLR board with an E3-1245v6 CPU (latest Firmware version 03.01.1029 installed)
I'm looking for the most basic SAS Module option with SAS 12 Gbps ports (that can operate without any RAID features active) so that the operating system has direct access to the hard drives for software defined storage solutions.
The S1200SPLR has a fourth expansion slot "SAS Module slot". However I'm unable to find a compatible SAS module for that motherboard. If you check the motherboard's product page under "Compatible Products" and "RAID Products", you only get regular PCIe add-in cards ("Low Profile MD2 Card"), nothing for that special SAS module slot.
Is there a product to supply the S1200SPLR's SAS module slot with a SAS 12 Gbps port?
Thank you very much for your help!
S1200BTSR connects cooler but no picture and no beep.
First of all I apologize for incorrect English, I'm using google translator. I have a s1200btsr with Xeon processor, it was working normally, suddenly it started to make a strange noise like it had a cable twisted in the cooler.
I try to call it already starts with this noise, as if a cable was catching on the cooler, or a bursting speaker. It has no beep and does not turn on the corner leds.
M.2 PCIe SSD in S2600BPB
Hello,
I have a Buchanan Pass system with the S2600BPB motherboard (XXLRE chassis, HNS2600BPB compute module). An Intel PCIe M.2 SSD is attached to riser slot 2 (back). However, the SSD is not visible in the OS.
* BIOS version: SE5C620.86B.00.01.0009.101920170742
* OS: CentOS 7.4
It's not just one bad system - I have 2 chassis, 8 modules; same issue.
If I add HHHL PCIe SSDs (P4600 for example), I can see the drives as /dev/nvme* devices.
Is there a BIOS setting that is needed? I have tried both UEFI and Legacy boot options.
When can we expect server board firmware updates for the recent vulnerabilities?
Unless I am just not searching your support site properly, I have not been able to find any server firmware updates to address the microcode updates for Meltdown or Spectre or even any notification of a time line. I have a few Intel server that are hosting virtualized environments and would like to see these patched as all of my other server vendors have already delivered these updates.
BMC LAN MAC Adress 00:00:00:00:00:00
Hello,
I have configured my BMC LAN for a static configuration using ipmitool. Once I was done I tried pinging it and didn't get a response. I noticed that my mac address was 00:00:00:00:00:00 but everything else looks correct. Has anyone seen this before or figured out how to correct it?
Intel Server Board - S7200AP
BIOS Version - S72C610.86B.01.02.0072.041620172102
#########
# ipmitool lan print 1
Set in Progress : Set Complete
Auth Type Support : MD5 PASSWORD
Auth Type Enable : Callback : MD5 PASSWORD
: User : MD5 PASSWORD
: Operator : MD5 PASSWORD
: Admin : MD5 PASSWORD
: OEM :
IP Address Source : Static Address
IP Address : XX.XX.XX.XX <-- omitted IP address
Subnet Mask : 255.255.255.0
MAC Address : 00:00:00:00:00:00 <--- WHY?
SNMP Community String : public
IP Header : TTL=0x00 Flags=0x00 Precedence=0x00 TOS=0x00
BMC ARP Control : ARP Responses Enabled, Gratuitous ARP Disabled
Gratituous ARP Intrvl : 0.0 seconds
Default Gateway IP : XX.XX.XX.XX <-- omitted GW.
Default Gateway MAC : 00:00:00:00:00:00
Backup Gateway IP : 0.0.0.0
Backup Gateway MAC : 00:00:00:00:00:00
802.1q VLAN ID : Disabled
802.1q VLAN Priority : 0
RMCP+ Cipher Suites : 0,1,2,3,4,6,7,8,9,11,12,13,15,16,17,18
Cipher Suite Priv Max : Xaaaaaaaaaaaaaa
: X=Cipher Suite Unused
: c=CALLBACK
: u=USER
: o=OPERATOR
: a=ADMIN
: O=OEM
############
# ipmitool bmc info
Device ID : 33
Device Revision : 1
Firmware Revision : 1.00
IPMI Version : 2.0
Manufacturer ID : 343
Manufacturer Name : Intel Corporation
Product ID : 117 (0x0075)
Product Name : Unknown (0x75)
Device Available : yes
Provides Device SDRs : no
Additional Device Support :
Sensor Device
SDR Repository Device
SEL Device
FRU Inventory Device
IPMB Event Receiver
IPMB Event Generator
Chassis Device
Aux Firmware Rev Info :
0x01
0x07
0x40
0x28
Thank you so much for your help.
How to set up mail reminder in Intel RSTe?
I use Intel's dual-server server S2600CP2 and Windows Server 2008 R2 operating systems. After installing the INTEL RSTE GUI, when setting up a mail reminder, after entering the SMTP mail server address and port and the sender and recipient email addresses, Send test mail each unsuccessful, for a lot of SMTP mail server address and port number, as well as the sender and the recipient's mail address will not work. And I was thinking, if you do not need to enter the login password of the mailbox, how can it send a test mail? I need to remind the function of mail, how should I properly set it, in order to normal use of the e-mail alert function.
Intel Embedded Server RAID Technology 2 is not visible under the Advanced tab
I use Intel's dual server S2600CP2 and Windows Server 2008 R2 operating systems. When I set up boot from EFI, Intel Embedded Server RAID Technology 2 could not be found under the Advanced Tab in BIOS, which means I could not use Human Interface Infrastructure Configuration Utility, how should I solve the problem, I checked a lot of Intel's technical documentation, did not find helpful to me.
S1200SPOR External (PCI-e) display adapter not working
Hi
We have connected a PCI-e display adapter (nVidia) inside this server, Windows 10 does not see any new hardware, we do not get any video from this adapter (on boot or Windows), we have the BIOS drivers loaded.
Are there any standards that need to be met in the new card for the system to see it? How can we tell in BIOS if it sees the new adapter?
The card we are testing (Jaton nVidia VIDEO-PX628GS-LP1), works in other Intel boards (DX79xx series).
Intel RAID (RMS3CC080), how to "Online RAID Expansion", cant find it in BIOS or RWC3
Hi
We have a S1200SPOR with RMS3CC080, the below document on page 6 (real PDF page 16) says this controller (and all others that are 12Gb) will:
"Online capacity expansion to add space to an existing drive or a new drive"
"Online RAID level migration"
Ive completed both of the above before with PROMISE controllers and LSI / AVAGO, however i can find anyway in the BIOS or with RWC3 (RAID Web Console 3) to do this, when i select the Virtual Drive there are no options to expand or change the RAID level.
So how is this done?
RWC3 doesn't accept notification email addresses which contains "-"
Hello,
I want to setup email notification in RWC3 and I'm not able to configure email addresses which contains "-" . I receive an error "Please enter a valid email id".
Is there a fix for this?
Thank you!
S2600CP Windows 10 watchdog driver
Good Day.
I am tried enable "OS boot watchdog timer" at BIOS, but my OS (Window 10 - 1709) always rebooted.
I didnt find Intel Watchdog driver and i dont understand how i should install it.
I am really need your help.
How i should check this driver? Does this function support Windows 10?
RMM Status : | Intel(R) RMM not installed |
Device (BMC) Available : | Yes |
BMC FW Build Time : | Mar 23 2017 20:14:24 |
BIOS ID : | SE5C600.86B.02.06.0006.032420170950 |
BMC FW Rev : | 01.28.10603 |
Boot FW Rev : | 01.17 |
SDR Package Version : | �� dd ddd |
Mgmt Engine (ME) FW Rev : | 02.01.07.328 |
Ipmitool lan print 1 returns Invalid channel: 1
Prior to replacing the 3V battery on the mother board, this command: "Ipmitool lan print 1" returned useful information. Now the command returns: Invalid channel: 1.
Did I lose a configuration setting and if so, what change do I need to make?
RAID of 5 disks on the R1208WTTGSR
I can not configure a software RAID of 5 disks on the R1208WTTGSR platform. Need raid 10 + 1 hot spare. In the BIOS, sata (0-3 port) and ssata (0-3 port) are available. It turns out that 2 different baskets! Accordingly, a raid can be created from only 4 disks! How to combine them into one basket? To make a raid you can create from 5, 6, 7 disks !!!
S1200BTSR connects cooler but no picture and no beep.
First of all I apologize for incorrect English, I'm using google translator. I have a s1200btsr with Xeon processor, it was working normally, suddenly it started to make a strange noise like it had a cable twisted in the cooler.
I try to call it already starts with this noise, as if a cable was catching on the cooler, or a bursting speaker. It has no beep and does not turn on the corner leds.
Intel® Server Board S1200SPL and Intel Xeon E3-1245 v5
I have a problem. Don´t work. I'm trying connect hardware but the motherboard beats, is it incompatible?