Problem with RAID controller

$
0
0

Hello !

 

Acquired RAID controller MegaRaid SAS 9240-8i

When connecting to the Intel C2600CW2R motherboard and running the Windows Server 2008/2012/2016

(tried different versions), a problem arose:

The controller in the system is detected with an error: This device can not be started

(code 10): hardware error of the I / O controller

Location: Socket PCI 257 (PCI-bus 7, device 0, function 0)

The manufacturer of the device LSI Korp.

 

I ask to respond to mail: si@nerkon.ru


Intel MFSYS35 Check Storage Controller Status.

$
0
0

Hello everybody!

Here is the problem: dashboard shows this message: "Check Storage Controller Status". When I click the SCM2 in management interface it shows: "Initializing (Offline)".

Our distribuitor ended up support of this model.

 

Thank you in advance!

How to clear a TPM2 so I can provision it again?

$
0
0

Hello everyone, first time posting here.

 

I am using the TPM 2.0 module AOM-TPM-9665 on a Supermicro X10SDV-TLN4F and I used the example AuthPolicy to provision it, through the uefi shell, and enabled TXT. I followed the instructions at [1].

 

I did that in order to better understand how I can provision TPM. But now I have created a new AuthPolicy with a custom pass phrase and I want to use this one. The problem is that when I try to clear the old authPolicy, when I run `ResetPlatformAuth.nsh sha256 EXAMPLE` I get the error "Did not satisfy PlatformPolicy Provisioning FAILED Setting PlatformAUth to EMPTY failed". What am I missing? Any suggestions?

 

tpm_error.png

 

I am pretty sure I haven't understood something correctly. If anyone can point me on where I can get more documentation on the correct usage of TPM, I will be grateful.

 

[1] https://www.supermicro.com/manuals/other/TPM.pdf

Had a melt down on a Win 2008 r2 with IRST.

$
0
0

Hi. I have a server that uses 3-3 Terabyte drives to create a RAID 5 system for data. Had a crash and the Intel manager software said it fixed the problem but Windows Server 2008 R2 does not see it as a drive anymore. Just un-allocated. I need the data off the RAID! Any help please.

Intel Accelerated Storage Manager installation on Windows Server 2016 Core

$
0
0

Hi I need to install Intel Accelerates Storage Manager to Windows Server 2016 Core and mainly to silently configure monitoring/sending emails when problem with HDD occured. I didnt find any manual, that told me how to do this? I see that there is some new feature (web ui), that maybe can be used to this? But I am not able to authenticate to it using local account..

Which std. (ITX/ATX) server (/or workstation) mobo for ESXi 6.5

$
0
0

Hi guys. Building a server used for SOHO back office and high end test/devel

 

I want the board to support ESXi 6.5 fully NICS, I/O passthruough. Furthermore it should:

 

1) have IPMI/iKVM

2) Support at least 64 GB DDR4, preferable 128 GB

3) low power usage

 

Any suggestions?

 

Regards, Lars.

Warranties (R1000SPO servers)

$
0
0

We have a part number :

 

SVCEWUPSY

 

What does this cover?  is it the complete server (board, CPU, case including PSU, backplanes and hard drvie carries?)  my point is, Lenovo offer warranty upgrades and it covers EVERYTHING in the server including CPU, RAM (if its Lenovo), Hard drives (also if Lenovo) and ALL hardware parts.

 

How do Intels work?

 

The above is 2 years, can we get longer?  Does it have to be ordered with the server or can it be done anytime in the first year?

Is this part number only for the R1200SPO hardware or is it on the S1200SPO generation of boards?

About Intel Black Box for common redundant power supply format question.

$
0
0

Hello ,

    I reading the CRPS design guide about PMBus Black box Command

The meaning as below:

 

        Name: MFR_BLACKBOX

        Format: Read Block with PEC (238 bytes)

        Code: DCh

 

The content have "System Tracking Data(47 bytes)" and "Power supply event data(38 byte per event)",

and the "Power supply event " can record 5 event,

so.. the total length of the command as 47 bytes + (38 bytes *5 ) = 237 bytes,

 

I calculated the result with the design guide length is not equal (238 byte ≠ 237bytes),

 

Is anyone knew the correct format about this command(DCh) , or can tell me what's detail I missed?

 

 

Alan Chen,


Decoding System Event Log data to get more information

$
0
0

Hello

 

I have a server workstation board and I am experiencing a system freeze with a CPU_CATERR - 

I am trying to understand the data in the system event log to see if it will point me in the right direction:

 

I tried using the document here: 

System Event Log Troubleshooting Guides for Intel® Server Boards

but to no avail. 

BMC-Owned Sensors (GID = 0020h) Section 3.1 Table 5 Does not have an entry for 0xDA.

 

Can anyone shed some light on this?

Board Has A C612 Chipset with 2 xeon E5 V4 2630 Processors on it.

 

Complete Info From the SEL Data:

 

04 00 02 2C A1 18

5A 20 00 04 07 DA

6F 00 FF FF

SENSOR # 0xDA

CPU_CATERR

Event Description IERR

RECORD TYPE 0x02

 

Thank You

RSP3TD160F compatible NVMe cables

$
0
0

Dear Sirs,

 

any idea whether there are cables available that will support the following? Have to use 3rd party Chassis.

 

1) RSP3TD160F to direct attach P4500 SSD series (SFF-8643 to SFF-8639 plus power). It seems that the broadly availabe cables with these specifications don't work. When using a PCIe Interface Card the SSDs are recognized, but when using Raid Card they are not. Heard about cables called "U.2 enabler cable". Anybody heard of it?

 

2) RSP3TD160F to a backplane using SFF-8643 for NVMe drives. Same Problem.

 

Hope anybody can give a hint.

 

Regards,

Sven

VGA problems S1200kpr

$
0
0

after i have disabled onboard VGA,

I'm unable to enable again,

even if i enable it in bios it still dont work

HPC S2600BP - System Cards

$
0
0

Listed below are the Queries,

 

1. Are the System Boards ( Interface Cards) Similar to the ones in a 2U system Or are the HPC node based System Card's Different ?

2. Related to the HSBP of the 4 Node S2600BP - can you provide us with relevant Detailed  information?

3. Are there Any Details Of the Chassis Drawing or Suppliers That we Can Get in touch with?

 

Awaiting for a Response.

ZAID

VEPL, INDIA

S2600CW2 board and LAN port failure

$
0
0

We have one server with S2600CW2 board and it has few issues with LAN port1:

When restarting server, BMC link fails for some period and then up again.

Using LAN port 1 not possible to do anything.

Have to use LAN2 and MGMT port to be able to do anything.

 

When trying to boot to PXE using LAN1 port, then it fails for many first attempts.

 

Can it be port 1 failure and need to change motherboard?

 

FW is the latest and greatest

 

Hope for hint and advice!

Can one use (install) two of FUP8X25S3NVDK in ONE P4304XXMUXX?

$
0
0

Can one use (install) two of FUP8X25S3NVDK in ONE P4304XXMUXX?

 

E.G. by using a Broadcom MEGARAID 9460-8I

 

If yes, will there be 4, 8, 16 nvme ssd usable?

S2600CP cannot boot if EFI optimized boot is enabled

$
0
0

Hello,

     I have a S2600CP2 board with a AMD R9 380 GPU installed on a pcie x8 slot. It work fine is EFI optimized boot is disabled. But as soon as I turn that on, it can't p*** the board self-check. The diagnosis led light as the imageQQ图片20171211101355.png

well, i had set Use Legacy Video for EFI OS to enabled but no working.

Any solutions?

Many thanks.


s2600cp BMC error help

$
0
0

I picked up a s2600cp that I am trying to get running. I have got the BIOS updated to the latest version (02.06.0006) after stepping through many upgrades.  I have 3 4pin fans plugged into system fan 1, 2 and 3.  I ran frusdr and configured those fans, all other fans off, and marked no for chassis intrusion.  Upon completing the config update the fans immediately spin down, but after the BMC reinitialized they ramp back up to full speed. I ran sysinfo and after digging through the log saw this:

Management Subsystem Health, BMC FW Health (#0x10) Warning event: BMC FW Health reports the sensor has failed and may not be providing a valid reading.

It I dug deeper and found that it started popping up somewhere during the bios updates(The version that I started with was so low i stepped through maybe 12 to be safe).  After seeing this I reflashed the BMC, and reflashed frusdr to no change. 

 

I have found very little after scouring the net for this error. I have seen some people say this means the board is failing, and I have seen some people say it means its reading something wrong.  Either way both pieces seem a bit vague.

 

I am fairly certain this is the cause of the full speed fans as the system status LED is flashing green and I believe a fault like this will trigger fans to run at max speed.

 

Also the system seems to be running fine other than this. Does anyone have any information that could shed some light on this?  Thanks

drastic reduction in performance when compute node running at half load

$
0
0

We have compute nodes with 24 cores( 48 threads) and 64 GB RAM (2x32GB). When I run a sample code (matrix multiplication)in one of the compute node in one thread, it takes only 4 seconds. But when I starting more runs (copy of the same program) in the same compute node, the time taken increases drastically. When the number of programs running reaches 24 (I gave maximum 24 since physically only 24 cores are present), the time taken becomes like around 40 seconds ( 10 times less). When I checked the temperature, it is below 40 deg Celsius.

 

When I searched in the Internet about this issue, I found some people saying that it may be due to slowing down of transfer of data from ram to processor when we run many programs. I was not satisfied with this comment, because the compute nodes are designed to run at maximum load with out much decrease in performance. Also, we are using only 1GB of memory even with 24 programs running. Since we are getting performance reduction of about 1/10, I guess the problem is something else.

Switch Module AXXSW1GB on Intel Modular Server MFSYS35 bootloop

$
0
0

How to fix my customer's Switch Module SW1 on Intel Modular Server MFSYS35 from bootloop ?

 

Here is the detail :

- the green led is blinking for a long time

- the orange led is steady for a long time

- when I see the terminal connection on serial (RS232 port) with telnet :

"

Boot1 Checksum Test...............................PASS

 

Boot2 Checksum Test...............................PASS

 

Flash Image Validation Test.......................PASS

 

 

 

BOOT Software Version 1.0.0.6 Built  30-May-2007  11:09:42

 

 

Intel ClearBay board, 88F5181 CPU based with ARM926EJ-S core.

128MByte SDRAM. I-Cache 32 KB. D-Cache 32KB. Cache Enabled.

 

Autoboot in 2 seconds - press RETURN or Esc. to abort and enter prom.

Preparing to decompress...

100%

Decompressing SW from image-1

100%

 

OK

Running from RAM...

 

*********************************************************************

*** Running  SW  Ver. 1.0.0.27  Date  21-May-2008  Time  10:42:27 ***

*********************************************************************

 

HW version is

Base Mac address is: 00:15:17:4f:94:e6

Dram size is  : 128M bytes

Dram first block size is  : 102400K bytes

Dram first PTR is  : 0x1800000

Dram second block size is  : 4096K bytes

Dram second PTR is  : 0x7C00000

Flash size is: 16M

01-Jan-2000 01:01:06 %CDB-I-LOADCONFIG: Loading running configuration.

01-Jan-2000 01:01:06 %CDB-I-LOADCONFIG: Loading startup configuration.

Devices on PCI BUS 0 (slot 0):

-----------------------------

id select = 31, dev type=0x5181

 

Device configuration:

---------------------

Slot 1       : AXXSW1GB

HW revision  : D70739-404

CPLD ID      : 128

CPLD Version : 2

Slot ID      : 0x1

IDROM size   : 103Bytes

ESM Module ID: 0.46

01-Jan-2000 01:01:08 %2SWINIT-F-INITCOREPPHWPHASE1: SW2P_core_pp_hw_phase1_init: Core PP HW phase 1 init failed - error msg Operation failed

 

***** FATAL ERROR *****

Reporting Task: ROOT.

Software Version: 1.0.0.27 (date  21-May-2008 time  10:42:27)

 

**************************************************

*****************  SYSTEM RESET  *****************

**************************************************

"

 

the hardware bootloop continuosly

s1200sps + supermicro sc825tq-r720lpb tracking power failures

$
0
0

intel s1200sps mainboard has the i2c ( SSI compliant 1x5 pin connector J9F1 to provide I2C monitoring of the power supply. https://www.intel.com/content/dam/support/us/en/documents/server-products/S1200SP_TPS_R1_1_S1200SPL_S1200SPS_S1200SPO.pdf) connector to track failures from psu on intel's own supported cases.

Has anyone managed to get supermicro's PDU (for example PWS-721P-1R) information of power failures?

 

When I test to plug out power cable I get OK readings from intel's bmc:

Name   Ascending  Status   Ascending  Health   Ascending  Reading   Ascending
Pwr Unit StatusAll deassertedOK0x0000

Br, Max

Wolf Pass Server 2600WFT Enumerates X710 PCI domain 10000 - DPDK will not load

$
0
0

I have a Wolf Pass 2600WFT Server where I am trying to load a DPDK-assisted vSwitch as I do on the Wild Cat Pass.

But DPDK fails to load because the Ethernet port is on PCIe domain 10000, instead of the normal 0000.

Is there some BIOS setting or update to make the domain for this Fortville NIC to be enumerated in domain 0000 ?

 

# ovs-dpdk -c 0x5 -n 4 -r 2 --socket-mem 1024,1024 --huge-dir /mnt/huge-1048576kB --file-prefix vs --proc-type primary -w 10000:01:00.0

DPDK failed to allocate requested resources...

# lspci | grep Eth

0000:3d:00.0 Ethernet controller: Intel Corporation Ethernet Connection X722 for 10GBASE-T (rev 09)

0000:3d:00.1 Ethernet controller: Intel Corporation Ethernet Connection X722 for 10GBASE-T (rev 09)

0000:af:00.0 Ethernet controller: Intel Corporation Ethernet Controller X710/X557-AT 10GBASE-T (rev 01)

0000:af:00.1 Ethernet controller: Intel Corporation Ethernet Controller X710/X557-AT 10GBASE-T (rev 01)

0000:af:00.2 Ethernet controller: Intel Corporation Ethernet Controller X710/X557-AT 10GBASE-T (rev 01)

0000:af:00.3 Ethernet controller: Intel Corporation Ethernet Controller X710/X557-AT 10GBASE-T (rev 01)

10000:01:00.0 Ethernet controller: Intel Corporation Ethernet Controller X710 for 10GbE SFP+ (rev 01)

10000:01:00.1 Ethernet controller: Intel Corporation Ethernet Controller X710 for 10GbE SFP+ (rev 01)

Viewing all 3923 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>