Quantcast
Channel: Intel Communities : Discussion List - Servers
Viewing all articles
Browse latest Browse all 3923

Error updating S2600KP firmware with OFU flashupdt

$
0
0

I encounter a couple of errors during the unattended update of the S2600KP firmware using OFU flashupdt

 

The errors are:

Error parsing CFG file at line 752. Missing parameter in FRUNAME

and

SDR auto-update failed

Error : Error while parsing the cfg file


The note in https://downloadmirror.intel.com/24717/eng/ReleaseNotes.txt about "SDR auto-update failed" does not seem to apply to my Windows installation. I could not find any information on the other error.

 

 

Does anyone have ideas on how to resolve these?

 

Thanks

 

flashupdt output:

C:\Install\OFU_V13_1_Build9_AllOS\Win_x86>flashupdt.exe -u C:\Install\S2600KP_SFUP_BIOS01010009_ME030007168_BMC0135r9065_FRUSDR109_updated\flashupdt.cfg

 

        One Boot Flash Update Utility Version 13.1 Build 9

        Copyright (c) 2015 Intel Corporation

 

Update file Configuration: XXX  S2600KP,1.0

 

Processing capsule file - C:\Install\S2600KP_SFUP_BIOS01010009_ME030007168_BMC0135r9065_FRUSDR109_updated\R0009.cap

 

Processing capsule file - C:\Install\S2600KP_SFUP_BIOS01010009_ME030007168_BMC0135r9065_FRUSDR109_updated\R0009_ME.cap

Update file Configuration: Revision S2600KP_109

FRU & SDR Update Package for Intel(R) Server Board S2600KPx (S2600KP_109)

Copyright (c) 2014 Intel Corporation

 

 

Intel(R) Server Board S2600KP detected

 

 

 

Processing FRU File C:\Install\S2600KP_SFUP_BIOS01010009_ME030007168_BMC0135r9065_FRUSDR109_updated\S2600KP.fru...

 

 

 

Processing BMC FW Controller

Querying USB Interface ...

Using USB Interface...

Sending update options to firmware: Done.

Transferring BMC Firmware Image:

100% Done.

BMC Firmware Update Status:

100% Done.

BMC Firmware Update Successful

This may take upto 50 seconds to exit. Please wait...

 

BIOS Update In Progress:  100%

Primary Update completed, Backup BIOS update will be completed in next boot.

BIOS has been updated successfully.

Please restart the server for the update to take effect.

 

 

ME Update In Progress:  100%

The ME Firmware has been updated successfully.

 

 

FRU Update Started

FRU Update......

100% FRU Update Successful

Reading System FRU

Reading System FRU  Done

FRU Verification Started

FRU Verification Successful

 

Auto-update for SDR through CFG Started

Updating CFG file ......

100%

Updating SDR file ......

100%

Parsing ......

Error parsing CFG file at line 752. Missing parameter in FRUNAME

 

 

FRU & SDR Update Package for Intel(R) Server Board S2600KPx (S2600KP_109)

Copyright (c) 2014 Intel Corporation

 

 

Intel(R) Server Board S2600KP detected

 

Auto-detecting chassis model and attached hardware.

This may take up to 1 minute to complete.

NODE Presence is present

 

Detected Hardware

********************************************************************************

Intel(R) Server Chassis H2000G Product Family

Intel(R) Server Board S2600KP

Intel(R) Xeon(R) Processor E5-2600 in socket 1

Intel(R) Xeon(R) Processor E5-2600 in socket 2

Baseboard FRU Device

1600 Watt Power Supply Module 1

Power Supply Module 1 FRU Device

1600 Watt Power Supply Module 2

Power Supply Module 2 FRU Device

Redundant Power Supply Configuration

HSBP is a 2U 16 slot 2.5 inch HDD Backplane

IO Module FRU Storage Device

IO Module Temperature Device

********************************************************************************

 

 

 

SDR auto-update failed

 

Error : Error while parsing the cfg file

 

 

C:\Install\OFU_V13_1_Build9_AllOS\Win_x86>


Viewing all articles